Get in touch with QJKH Company
CCH · Machine Safety Control
SRB-2A1B Safety Relay Module
Monitor compatible dual-channel safety-device signals and interface with downstream machine safety circuits. Supports selectable NPN / PNP inputs, manual or automatic reset, and dedicated muting control inputs.
- NPN / PNP
- Selectable dual-channel input
- 2 NO + 1 NC
- Relay contacts
- <10 ms
- Module response time
- 24 VDC ±10%
- Operating supply
Core Functions
From Protective Signals to Relay Outputs
Dual-Channel Monitoring
Monitors compatible safety-device signals, with selectable dual NPN or dual PNP input modes and channel-consistency monitoring.
Reset & Muting Control
Manual or automatic reset configuration, with dedicated MUT_H / MUT_L inputs for the documented muting / shielding function.
Status & Installation
CH1, CH2, ERROR and POWER indicators, reverse-polarity protection, detachable terminals and 35 mm DIN-rail mounting.
Safety Device Integration
ENT Safety Light Curtains
Dual-channel monitoring for the documented ENT integration. Match the SRB input mode to the selected light curtain’s output configuration.
Explore ENT Light Curtains →SH Safety Laser Scanners
Monitoring of compatible SH safety signals where the electrical interface and safety architecture are suitable. Confirm the exact scanner output before integration.
Explore SH Safety Scanners →Control & Wiring Reference
Reset, Muting and Terminal Connections
Manual Reset
Requires the defined reset action after the protective input condition is restored. The documented ENT arrangement uses an external reset switch in the SR / SRC path.
Automatic Reset
Allows the relay to recover when the required input conditions are restored. The documented automatic-reset arrangement directly connects SR and SRC.
Reset is not machine restart. Select the reset mode and restart-prevention measures for the actual machine safety design. Restoring a protective field does not by itself establish permission for hazardous motion.
Muting / Shielding Control
MUT_H and MUT_L are SRB control inputs. In the documented CCH arrangement, an ENT safety light curtain works with two external photoelectric sensors, two ordinary relays and the SRB-2A1B. Muting is not built into the ENT light curtain.
The documented SRB muting state uses MUT_H at 24 V and MUT_L at 0 V; in this state, the connected light curtain signal does not affect the relay module. This state alone is not a complete muting design. External sensing, timing, wiring and machine response must be defined for the application.
View the Safety Light Curtain Muting Guide →Terminal Reference
| Terminal | Documented Function |
|---|---|
| S12 / S22 | ENT OSSD1 → S12; ENT OSSD2 → S22. Match the NPN / PNP selector to the actual ENT output configuration. |
| SR / SRC | Reset control: external reset switch for manual reset; direct connection for automatic reset. |
| MUT_H / MUT_L | Dedicated muting / shielding control inputs. |
| 13–14 / 23–24 | Two normally open passive relay contact pairs. |
| 41–42 | Normally closed auxiliary contact pair. |
Wiring scope: The input example above is specific to documented ENT integration; do not reuse it as an unverified SH wiring diagram. These references are not a complete machine electrical drawing. Follow current device instructions, disconnect power before wiring, and validate the complete safety function before commissioning.
Technical Data
SRB-2A1B Specifications
Product values and ratings stated in CCH SRB-2A1B documentation.
| Parameter | SRB-2A1B |
|---|---|
| Stated safety ratings | Cat. 4 · PL e · SIL 3 |
| Operating voltage / power | 24 VDC ±10% / <3 W |
| Safety input | Dual NPN or dual PNP, selectable |
| Relay output | 2 NO + 1 NC passive contacts; NC contact is auxiliary |
| Contact capacity | AC15: 5 A / 250 V DC13: 6 A / 24 V |
| Electrical life | ≥1,000,000 operations; dependent on switching conditions and load |
| Response time | <10 ms |
| Pull-in delay / power-on startup | <50 ms / <1 s |
| Operating temperature | −30 to +50°C; no frost or condensation |
| Storage temperature | −40 to +70°C |
| Operating / storage humidity | 35–85% RH / 35–95% RH; avoid condensation |
| Protection rating | IP20 |
| Dimensions | 114.5 × 99.5 × 22.5 mm |
| Mounting / terminals | 35 mm DIN rail / detachable terminals |
| Standards referenced in documentation | EN ISO 13849 · IEC 61508 · IEC 62061 · EN 61000-4 series |
Safety-performance scope: The stated component ratings do not automatically establish the machine’s Category, PL or SIL. Complete performance depends on the input, logic, output, architecture and validation. The module response time is only one part of total system response. Standard references are not an independent third-party certification claim.
Installation: provide an enclosure suitable for the machine environment, confirm the contact load and supply, and observe the documented temperature and humidity limits.
Selection Support
Plan Your SRB Integration
What information should I provide for model and interface review?
Send the protective-device model, output signal type, NPN / PNP requirement, machine supply, downstream control circuit, required safety performance, and any reset or muting requirements.
Can I use SRB-2A1B with a different protective device?
Compatibility depends on the exact output signals, electrical interface and safety architecture. Provide the device’s technical documentation so these can be checked for the intended application.
Which details matter for a material-transfer application?
Include the opening and load dimensions, direction of travel, operating sequence, sensor arrangement and possible personnel access. These details help define the application-specific muting requirements.
Discuss Your Machine Safety Application
Share your device model and control requirements for SRB-2A1B selection and integration support.
Contact Us