Safety Distance Calculator (ISO 13855)

Free Engineering Tool
Safety Distance Calculator (ISO 13855)

Calculate the minimum mounting distance between a safety light curtain and the hazard zone. Based on IEC/ISO 13855:2010 — the international standard for positioning safeguards relative to human approach speeds.

S = K × T + C

S = Minimum safety distance (mm)

K = Approach speed: 2,000 mm/s (hand/arm), 1,600 mm/s (whole body)

T = Total system response time = light curtain response + machine stopping time

C = Penetration allowance: 8×(d−14) mm for d ≤ 40 mm; 850 mm for d > 40 mm

where d = detection capability (resolution) of the light curtain in mm

Enter Your Parameters
ENT range: 6.0–30.8 ms (varies by beam count)
Typical: 50–500 ms — verify with machine manufacturer
ISO 13855 Result
Minimum Safety Distance
Total Response (T)
Penetration (C)

This calculator provides reference values per ISO 13855:2010. Always verify with your machine’s actual stopping performance measurement and a qualified safety engineer before finalizing installation. Machine stopping time must be measured, not estimated.

Worked Example: ENT-14 on a Mechanical Press

Configuration: ENT-14 with 32 beams (resolution d = 14 mm), light curtain response time = 10.2 ms, machine braking time = 100 ms.

S = 2,000 × (0.0102 + 0.100) + 8 × (14 − 14) = 2,000 × 0.1102 + 0 = 221 mm

At 221 mm from the press opening, the ENT-14 provides finger-level detection while allowing comfortable operator reach. A competitor unit with a 12 ms response time would require 244 mm for the same press — every millisecond of response time adds 2 mm of required safety distance at hand approach speed.

Quick Reference: Common Configurations
ApplicationModelMachine StopSafety Distance
Mechanical press (fast stop)ENT-1480 ms181 mm
Mechanical press (typical)ENT-14150 ms321 mm
Hydraulic press (hand guard)ENT-25200 ms509 mm
Press brake (near-distance)ENT-1450 ms121 mm
Robotic cell (body detection)ENT-45300 ms1,347 mm