SH27 SERIES
Safety Laser Scanners
Type 3 Safety Laser Scanners for AGV, AMR & Industrial Area Protection
CCH SH27 safety laser scanners provide configurable 2D protective field monitoring for mobile robots, automated vehicles and stationary machinery. With 3 m or 5 m protective ranges, a 276° scanning angle and up to 64 configurable zone sets, the SH27 series enables flexible safeguarding for changing industrial environments.
Choose the Right Safety Laser Scanner
Select the protective range first, then determine whether the application also requires Ethernet raw scan data. S models provide safety scanning with PNP OSSD outputs. D models retain the same safety functions and additionally provide non-safety Ethernet raw scan data for host-side processing.
Safety scanning model for applications requiring a 3 m protective range and PNP OSSD safety outputs without Ethernet raw scan data.
Combines the 3 m safety-rated protective function with supplementary Ethernet raw scan data for navigation, localization and other host-side processing.
Extended-range safety scanning model for applications requiring a 5 m protective range and PNP OSSD safety outputs without Ethernet raw scan data.
Combines the 5 m safety-rated protective function with supplementary Ethernet raw scan data for navigation, localization and other host-side processing.
Range First. Data Interface Second.
Select SH27-03S or SH27-05S when the application requires the SH27 protective function and OSSD outputs without Ethernet raw scan data.
Select SH27-03D or SH27-05D when the same safety functions are required together with Ethernet raw distance, angle and echo-intensity data.
PROTECTIVE & WARNING FIELDS
Protective Zone vs. Warning Zone
The SH27 series supports configurable protective and warning fields for different safeguarding and signaling requirements. These fields serve different functions and should not be treated as equivalent.
Protective Zone
The protective zone is used for safety-related object detection. When an object enters the configured protective field, the corresponding OSSD safety output switches to the OFF state so that the connected control system can initiate the required safe response.
- Used for personnel safeguarding and collision protection
- Safety-related monitoring field
- Detection causes the corresponding OSSD output to switch OFF
- 3 m or 5 m protective range depending on model
Warning Zone
The warning zone provides non-safety-related object detection. It can be used for signaling or pre-warning functions such as warning lights or audible alarms.
- Used for pre-warning and signaling
- Non-safety-related monitoring field
- Can activate warning lights or audible alarms
- 10 m or 20 m warning zone depending on model
Flexible Protective Fields for Changing Operating Conditions
The SH27 series supports up to 64 configurable zone sets, allowing protective and warning fields to be adapted to different machine states, travel directions and AGV operating conditions.
Configurable Zone Sets
Preconfigured field shapes can be stored and selected according to the operating condition of the machine or mobile platform.
Switch Fields by Control Inputs
Preconfigured zone sets can be selected through control inputs, allowing the active monitoring field to change with machine states or operating modes.
Speed-Dependent Protective Field Switching
Dynamic control inputs can be used with incremental encoder signals to select protective fields according to AGV travel speed.
Two Independent Protective Zones
The SH27 can operate with two protective zones, with each zone assigned to its corresponding OSSD output pair for independent safety monitoring.
SH27 Series Technical Specifications
Core specifications shared across the SH27 safety laser scanner series. Protective range and warning zone depend on the selected model.
Type 3 / SIL 2 / PL d / Cat. 3
Safety performance according to the applicable standards specified for the SH27 series.
S or D Version
S models provide safety scanning functions. D models retain the safety functions of the S version and additionally provide Ethernet raw scan data for AGV navigation.
Safety Laser Scanners for Mobile Robots and Industrial Safeguarding
The SH27 series is designed for both mobile and stationary safeguarding applications. S models focus on safety protection, while D models add Ethernet raw scan-data output for AGV natural navigation.
AGV & AMR Safeguarding
Configurable protective fields help detect people and obstacles around moving automated vehicles. Field switching can be adapted to different vehicle speeds and operating conditions.
- Personnel safeguarding around moving vehicles
- Collision protection for AGV and AMR platforms
- Speed-dependent protective field switching
- Multiple configurable zone sets
AGV Navigation & Localization
S models provide safety scanning functions, while D models additionally provide Ethernet raw scan-data output for AGV navigation and higher-level data processing.
- Distance data
- Angle data
- Echo intensity data
- Raw scan data through Ethernet
Machine Safeguarding
The SH27 can monitor hazardous machine areas where fixed guards are impractical or where access to the protected space must remain open during normal operation.
- Hazardous area monitoring
- Access protection
- Configurable protective zones
- OSSD safety output for machine stop functions
Industrial Area Protection
Configurable monitoring fields can be used to protect open industrial areas, material handling zones and other locations where a flexible two-dimensional detection field is required.
- Open area safeguarding
- Material handling zones
- Protected access routes
- Warning and protective field combinations
Designed for Safety-Related Industrial Applications
The SH27 series is specified for safety-related protective monitoring in mobile and stationary applications, with safety performance up to Type 3, SIL 2 and PL d / Category 3 according to the applicable standards.
Safety laser scanner performance classification.
Functional safety integrity level stated for the SH27 series.
Performance level and category for safety-related control functions.
Protection rating specified for industrial operating environments.
Dual OSSD Pair Capability
The SH27 supports two OSSD output pairs. In dual protective zone mode, Protective Zone 1 is assigned to OSSD1 and Protective Zone 2 is assigned to OSSD2 for independent safety monitoring.
Class 1 Laser Product
The SH27 uses a 905 nm laser source and is specified as a Class 1 laser product in the manufacturer documentation.
Technical Documents for the SH27 Series
Access product specifications, operating information and engineering support for SH27 safety laser scanner selection, integration and application setup.
SH27 Series Datasheets
Technical specifications and model information for SH27-03S, SH27-03D, SH27-05S and SH27-05D.
Request Datasheet →Installation & Configuration Guide
Operating information covering installation, configuration, protective field setup, I/O functions and SH27 operating procedures.
Request Manual →Application & Model Selection Support
Need help selecting the correct model or configuring protective fields for an AGV, AMR, machine or industrial area application?
Ask Our Engineers →SH27 Safety Laser Scanner FAQ
Common questions about model selection, safety functions, protective fields and AGV navigation capabilities.
What is the difference between SH27 S and D models?
S models provide the safety scanning functions of the SH27 series, including configurable protective fields and PNP OSSD safety outputs. D models retain these safety functions and additionally provide Ethernet raw scan data for AGV natural navigation and higher-level data processing.
What is the difference between the 03 and 05 models?
SH27-03 models provide a 3 m protective range and a 10 m warning zone. SH27-05 models provide a 5 m protective range and a 20 m warning zone. The required model should be selected according to the safeguarding distance and application layout.
Is the warning zone a safety-related protective field?
No. The warning zone is non-safety-related and is intended for pre-warning or signaling functions. It must not be used as a safety-related protective field.
Can the SH27 be used on AGVs and AMRs?
Yes. The SH27 can be used for AGV and AMR collision protection and personnel safeguarding. Configurable and speed-dependent protective field switching can be used to adapt the monitored area to different vehicle operating conditions.
Can the SH27 D-series provide scan data for AGV navigation?
Yes. D-series models provide Ethernet raw scan data such as distance, angle and echo intensity data, which can be used by higher-level AGV navigation, localization or mapping systems.
How many configurable zone sets does the SH27 support?
The SH27 supports up to 64 configurable zone sets. These can be selected according to machine states, travel direction or AGV operating conditions.
Is the Ethernet output safety-related?
No. The Ethernet raw-data output is non-safety-related. Safety functions are implemented through the scanner’s safety outputs, including the PNP OSSD output pairs.
Can the SH27 monitor two protective zones independently?
Yes. In dual protective zone mode, Protective Zone 1 is assigned to OSSD1 and Protective Zone 2 is assigned to OSSD2 for independent safety monitoring.
Need Help Selecting the Right SH27 Safety Laser Scanner?
Send us your application requirements and our engineers can help identify the appropriate SH27 model, protective range and field configuration for your machine, AGV or AMR.
AGV, AMR, machine or industrial area
Tell us the safeguarding distance or working area
Let us know if Ethernet raw scan data is required
Discuss Your Application
Not sure whether you need SH27-03S, SH27-03D, SH27-05S or SH27-05D?
Send us your application details and we will help you select the appropriate SH27 model and field configuration.
Contact Our Engineers →