Safety Distance Calculation for Machine Guarding: A Stop-Time Audit

In this hypothetical drive trace, the machine stops 180 ms after the drive receives the stop command. Before you use that number in a safety distance calculation, figure out what initiated the timer. A drive trace that starts with the drive receiving a stop command leaves out the time it took the light curtain and safety controller to send that command. A safety distance calculation is the determination of how far a safeguard must be from a hazard for the applicable approach and response time.

To calculate safety distance for machine safeguarding, begin with the applicable method, the overall response time and the allowances for the installed safeguard. Describe where the timer begins, where dangerous motion ends and what access ways the installed safeguard must protect in the audit.

Keep three items with the calculation

  • A trace showing timing and end points.
  • An as-built drawing showing the detection zone, the hazard and relevant pathways.
  • The safety settings, and the means used to assess stopping and detection.

What does a machine safety distance calculation cover?

Separates method selection, timing and reaching inputs before a distance is calculated.

A machine safety distance calculation estimates the minimum distance needed for the specified safeguard to start the protective action early enough to stop hazardous motion before a person can reach it. The review identifies the accessible hazard and the protective field along the person’s approach route.

A distance measured from the front of the cabinet or the edge of a mounting bracket may miss both references.

ISO 13855:2024 covers the positioning and dimensioning of safeguards in relation to human approach. For the static case described in Pilz’s positioning guidance, the equation is S = (K × T) + DDS + Z. In that expression, S is separation in millimeters, K is the applicable approach speed in millimeters per second and T is the overall system response time in seconds. DDS is the applicable reaching allowance and Z is an application-dependent supplemental distance. Select K for the actual approach. Pilz gives 100 mm as the minimum separation distance in this method. Determine the governing reaching allowance from the applicable through, over and under cases, then check which supplemental distances apply to the equipment and installation.

For the case described by Pilz, an initial result above 500 mm using 2,000 mm/s may allow recalculation at 1,600 mm/s. In that case the result still has a 500 mm floor. Check the applicable method before changing the approach speed. ISO’s derived separation distances do not apply to safeguards used solely for presence sensing.

Check the edition on any worksheet inherited from a previous job. If it contains a single term called C, check with the original designer for edition and approach case it represents. Keep the inputs in the new record under terms used by the applicable method. For device placement and approach, see our light curtain distance calculation guide.

In the United States, OSHA 29 CFR 1910.217 sets requirements for covered mechanical power presses. For the presence-sensing case in paragraph (c)(3)(iii)(e), the rule requires a distance greater than the product of 63 inches per second and the press stopping time in seconds, measured at approximately 90 degrees of crankshaft rotation. Press brakes and hydraulic and pneumatic power presses are among the exclusions listed in the section. Presence sensing device initiation, or PSDI, has its own provisions in paragraph (h). Determine the machine and operating mode before selecting a calculation method.

Where does the stop-time measurement start and end?

Makes the stop command visible as an intermediate marker between sensing and the end of hazardous motion.

To verify a light curtain that initiates a stop, state the event that actuates the protective function and specify where the defined hazardous motion has ceased. If the protection instrument is triggered from the curtain safety output or a drive system input, name that event and explain any relevant time prior to that.

A qualified tester can capture the overall stop on an installed manufacturing machine using the prescribed method. When using the calculated route, trace the steps that the applicable method requires, such as sensor response, safety input and logic processing, output switching and the time until the machine stops. Include a relevant timing tolerance or allowance in its appropriate location. Compare endpoints to determine what has been added. A trace that covers curtain actuation through the cessation of hazardous motion includes the safety logic between those events.

Timing markers for a light curtain stop
Trace marker What it identifies Where to verify it
Protective device actuated The event that starts the protective response. Test trigger or detection event on the synchronized trace.
Stop command arrives The boundary between the upstream controls and the part of the stop measured at the final control element. Identified signal and machine documentation.
Hazardous motion ceases The end event for the motion under review. Motion channel and stated criterion for the test.

Choose test conditions that cover the credible slowest response for the safety function. The validation plan should say which speed, load, direction and cycle conditions matter for this equipment. A measurement taken with an unloaded or slow machine may miss the operating condition that governs placement. Keep the readings and the selection criterion together. For new machinery, Pilz describes using the highest of 10 measurements when applying the documented measurement route. Follow the method and equipment requirements that apply to the actual test.

The OSHA press safety distance eTool differentiates the response of the sensor and interface, control response, machine stopping and brake monitor allowance, if applicable. Its example is related to press safeguarding.

Worked example: the missing 40 milliseconds

Shows the interval that disappears when timing starts at the drive.

In this hypothetical trace, the light curtain is interrupted at 0 ms. The drive receives its stop command at 40 ms. The hazardous motion ceases at 220 ms. The 40 ms before the command belongs to the upstream portion. A timer started at the drive runs for 180 ms. A timer for the entire illustrated response runs for 220 ms.

Illustrative trace with a fixed approach coefficient
Timing input Time in seconds Travel term at 2,000 mm/s
Drive command to stop 0.180 s 360 mm
Curtain interruption to stop 0.220 s 440 mm
Difference from the omitted interval 0.040 s 80 mm

Both timing cases use the same assumed approach speed of 2,000 mm/s. The approach speed K is 2000 mm/s for upper limbs or 1600 mm/s for walking. The drive-only product is 0.180 s × 2,000 mm/s = 360 mm. For the full trace it’s 0.220 s × 2,000 mm/s = 440 mm. Multiplying the omitted 0.040 s by that speed gives an 80 mm difference in the travel term. The illustration uses the travel term from Pilz’s static positioning method. The figures describe the effect of leaving out one interval. To determine an installed distance, the applicable approach, allowances, measurement conditions and actual field dimensions still have to be established.

Go back to the worksheet to trace the start event associated with each timing entry. Using end-to-end readings, mark upstream intervals as included. If the reading began at the drive, use verified evidence to fill the gaps. This procedure helps identify a calculation that adds the same sensor delay twice or omits part of the protective response.

Which route lets someone reach the hazard first?

Highlights approaches that can bypass a single protected opening.

Consider the protective design and check access to the hazard through, over, under and beside the installed field. One example of through field access is a perpendicular approach through the detection field. A person standing next to a fixture can sometimes reach over the top. A gap near the floor or a clear side route can also change which hazard is accessible and the protective design’s response.

Approach routes to compare on the as-built drawing
Route Evidence to check
Through the detection field Effective detection capability in the active mode, including whether the specified function is finger, hand or body protection, the relevant height and the position of the nearest accessible hazard.
Over or under the field Installed field edges and surfaces a person can stand on or reach from. Check the applicable reaching allowances.
From an adjacent walkway Approach to the same hazard from the neighboring work station or service aisle.
From a raised surface Check whether a step, fixed platform or accessible ledge changes where an operator can reach.
Beside the largest workpiece Verify whether the occupied opening leaves a route next to the load and how that route is guarded.
Through a tooling opening Check the access that remains with each tool or fixture covered by the validation plan.
From the rear of the machine Identify any access that never intersects this detection field and confirm its protection.
Around the field Side gaps and alternate access routes. Confirm what protects each route that avoids detection.
Past the field Potential space for a person to remain inside. Verify how presence and restart are addressed by the risk assessment and safety function.

Test the actual workpiece and surrounding components per the manufacturer’s evaluation. Reflective fixtures and shiny stock can make a difference even if the curtain is in the same position. Washington’s light curtain rule highlights this issue for installations within its jurisdiction. Record the approach geometry as well as evidence the configured safeguard detects what the application requires.

Use the actual approach method. SICK’s sBot Speed instruction manual, Section 4.4.2, shows a case of a parallel approach to a scanner protective field with its own inputs. A horizontal field has its own geometry and configured response. The safety laser scanner guide shows how field selection and scanner settings relate to a machine safety review.

What changes trigger a new check?

Shows common changes that can invalidate separate parts of the earlier record.

Reopen the validation record when a change could affect response time, the hazard location, or the active detection capability. A brake or drive adjustment can affect the stop. A tool can change the location of the nearest hazard. Moving a work surface can provide a reach-over route even though the curtain and its brackets stay in the same place.

Keep the safety settings with the report. If safety software changes, identify the version that was present in the engineering test record. In the manufacturer’s one-beam reduced-resolution example in the SICK deTec4 instructions, a light curtain with a 14 mm physical resolution has a 24 mm effective resolution. For that setting, the manual also gives 10 mm as the maximum ignored object size. This number describes object tolerance. Use the 24 mm effective resolution when reviewing the applicable positioning input for the example. Other modes, including combinations with Smart Box Detection, have separate conditions in the manual. The guide to muting and blanking describes how different configuration changes affect the protective function.

Wear can change stopping performance while the configuration remains the same. The UK HSE inspection guidance ties inspection frequency to the risk, conditions of use and potential deterioration. Set the inspection plan for the machine and retain the baseline readings so later measurements can be compared under equivalent conditions. If performance drifts, review the impact on the affected safety function with the person responsible for validation.

What should a commissioning report include?

Shows the three deliverables a reviewer should be able to locate independently.

Ask for the timing evidence, as-built dimensions and validation decision as separate items. That way, other reviewers can repeat the calculations and determine the part of the installation which was subject to the testing. The Stop-Time Trace Card provides the calculation transfer team with one location to record what goes with the calculation.

Stop-Time Trace Card
Record category What belongs in it
Machine and safety function Machine ID, operating mode, protected hazard and how the relevant protective action is initiated.
Method and settings Applicable rule or standard edition, active light curtain or scanner settings, response time data and configuration revision.
Conditions and traces Instrument and calibration record, test speed, load, direction, trigger, end criterion, all readings and how the value was selected.
As-built approach checks Detection field position, installed distance to each relevant hazard, reaching allowances and evidence for routes around or beyond the field.
Timing calculation Record each included interval, the conversion from milliseconds to seconds, the source of any added interval and any applicable tolerance.
Distance calculation Record the governing case, approach coefficient, reaching allowance and supplemental distance. Show how the required separation compares with the as-built dimensions.
Detection checks Record the test conditions for workpiece position, reflective surfaces and configured detection. Attach results to the specific operating mode.
Change record List revisions to the guard, drive, tool and safety settings with dates. Identify the revised evidence to use at the next review.
Review and follow-up Who reviewed the installation, the outcome of affected tests, open items and conditions that call for reinspection.

A retrofit quote should indicate who will measure the actual machine, check the installation against the drawings, and close any item that prevents completion of the acceptance testing. Distinguish the work to select the hardware from the work described above. For example, the OSHA industrial robot technical manual contains a review of robot applications validation drawings, control settings and tests of sensors. In robotic cells and custom machine building, the hand-off should identify who verifies the installed safeguards and how required safety level for each safety function was determined.

For supported perpendicular light curtain cases, the Pilz calculator employs safeguard and machine response information and the geometry for reaching over, through and under. The SICK stop time measurement service covers measurement and documentation for distance. Ask what event initiates measurement and which application conditions the report covers.

Use CCH’s safety distance calculator for an early check within its stated scope. This browser-based software tool covers a static, perpendicular approach to a vertical light curtain and has separate fields for device response, safety control response, machine stopping time and timing tolerance. Its stated effective detection capability limit is 55 mm. Before using a whole-chain measurement, check timing limits. The free tool screens one case. Record the exact model and operating mode when checking a Type 4 light curtain or another device. For a safety light curtain selection review, bring the proposed model, configured operating mode and validated stopping evidence to the discussion.

FAQs about safety distance calculation

What is the formula for a machine safety distance calculation?

For a fixed safeguard in the static ISO 13855:2024 case described by Pilz, add the distance traveled during the overall system response time to the applicable reaching allowance and any application-dependent supplemental distance. Select the approach method for the actual protective device and hazard. The method and required inputs can change with the application.

Is the stopping time on the drive display enough?

The drive display will serve its purpose only if its timing boundaries cover the response required by the selected method. Establish what event starts the timer and what event stops it. If timing begins only after the safety logic and the sensing element have acted, establish the missing part of the response separately or measure the overall stop from the appropriate starting event.

Can I use a vertical light curtain calculator for a horizontal scanner field?

No. Use the scanner method and manual for its active protective field and approach direction. A scanner may have application-specific field height limits, response settings, and supplemental distances. Verify these conditions against the actual installation before relying on a calculated field dimension. A tool built for a vertical curtain covers a different approach case.

Why do I need to check reach-over and reach-under?

Someone may reach the hazard by a route other than straight through the sensing field. Look at the actual field limits and examine all positions, including raised surfaces and gaps. Use the appropriate approach method for each of the routes. If an access route bypasses the field, the approach path must also be protected and verified. Compare the dimension with the latest as-built cell. Also determine whether a new work platform or work surface has altered the accessible approach.

When should the stop time be checked again?

Review the stop-time evidence after a change that can affect the safety function. Examples include different brake or drive settings, increased speed or load, new tools, and altered sensors or controller configurations. Inspection schedules should align with the applicable requirements and machine’s validation plan.

Does OSHA prescribe one formula for every machine?

No. OSHA 1910.217 applies to covered mechanical power presses and has different provisions for PSDI. For a covered press, identify the applicable OSHA subsection for the safeguarding device and operating mode before collecting the timing inputs that the chosen method requires.

Can I use a spreadsheet to sign off the installation?

No. Installation sign-off requires field measurements and test data. Use a spreadsheet to show inputs and calculations. Its calculation can’t confirm where the machine becomes hazardous, where a person can approach, or when the installed machine stops. The commissioning record should identify the verified configuration and test conditions and link to the evidence accepted by the person responsible for validation.

References & Sources

  1. ISO 13855:2024, positioning of safeguards
  2. IEC 62046:2026, application of protective equipment
  3. Pilz, positioning under EN ISO 13855:2024
  4. Pilz, safety distance calculator and reaching inputs
  5. OSHA, mechanical power presses under 29 CFR 1910.217
  6. HSE, HSG180 application of electro-sensitive protective equipment
  7. SICK, stop time measurement service and documentation
  8. SICK, sBot Speed operating instructions, section 4.4.2
  9. SICK, deTec4 operating instructions, Table 21