{"id":4523,"date":"2026-11-09T03:06:02","date_gmt":"2026-11-09T03:06:02","guid":{"rendered":"https:\/\/industrialsafetysensor.com\/?p=4523"},"modified":"2026-11-09T03:06:02","modified_gmt":"2026-11-09T03:06:02","slug":"ossd-wiring-guide","status":"publish","type":"post","link":"https:\/\/industrialsafetysensor.com\/pt\/blog\/ossd-wiring-guide\/","title":{"rendered":"Guia de fia\u00e7\u00e3o OSSD: pinout, polaridade PNP vs. NPN e integra\u00e7\u00e3o de rel\u00e9 de seguran\u00e7a"},"content":{"rendered":"<article class=\"ecc-blog-article\" itemscope itemtype=\"https:\/\/schema.org\/TechArticle\">\n<header class=\"article-header\">\n<p class=\"editorial-byline\">Por CYH \u00b7 Revisado pela equipe de engenharia de seguran\u00e7a da CCH Shanghai Technology and Intelligence Co Ltd<\/p>\n<p class=\"answer-first-lead\">Um Guia de Fia\u00e7\u00e3o OSSD ilustra como conectar uma sa\u00edda de seguran\u00e7a de canal duplo (OSSD1 e OSSD2) a um rel\u00e9 de seguran\u00e7a ou CLP de seguran\u00e7a em percursos de 1 a 300 m. Ambos os canais fornecem 24 V durante a opera\u00e7\u00e3o normal e caem para 0 V dentro de 10 a 20 ms quando acionados. Pulsos de teste escuros de 150 us a 1 ms s\u00e3o executados a cada 100 a 200 ms para detectar curtos-circuitos nos fios automaticamente.<\/p>\n<\/header>\n<nav class=\"article-toc\" aria-label=\"\u00cdndice\">\n<p><strong>Neste Guia de Engenharia:<\/strong><\/p>\n<ol>\n<li><a href=\"#h2-1\"> O que \u00e9 sa\u00edda OSSD? como os pulsos de teste de canal duplo detectam falhas na fia\u00e7\u00e3o<\/a><\/li>\n<li><a href=\"#h2-2\">C\u00f3digos de cores padr\u00e3o OSSD Pinagem e fio: conectores M12 de 5 pinos versus 8 pinos<\/a><\/li>\n<li><a href=\"#h2-3\">PNP Sourcing vs. NPN Sinking OSSD Wiring: Regras de polaridade e refer\u00eancia comum de 0V<\/a><\/li>\n<li><a href=\"#h2-4\">Como conectar OSSD1 e OSSD2 a um rel\u00e9 de seguran\u00e7a com EDM e redefinir feedback<\/a><\/li>\n<li><a href=\"#h2-5\">Conectando sa\u00eddas OSSD a um PLC de seguran\u00e7a ou controlador de seguran\u00e7a: configura\u00e7\u00f5es de pulso de teste e discrep\u00e2ncia<\/a><\/li>\n<li><a href=\"#h2-6\">Fia\u00e7\u00e3o OSSD espec\u00edfica do dispositivo: cortinas de luz de seguran\u00e7a versus scanners a laser de seguran\u00e7a<\/a><\/li>\n<li><a href=\"#h2-7\">Fia\u00e7\u00e3o em s\u00e9rie e dispositivos OSSD m\u00faltiplos em cascata: evitando o mascaramento de falhas sob ISO\/TR 24119<\/a><\/li>\n<li><a href=\"#h2-8\"> Limites de carga el\u00e9trica, capacit\u00e2ncia do cabo e c\u00e1lculos de comprimento m\u00e1ximo do fio<\/a><\/li>\n<li><a href=\"#h2-9\">Solu\u00e7\u00e3o de problemas Lista de verifica\u00e7\u00e3o de especifica\u00e7\u00f5es de fia\u00e7\u00e3o e compras do OSSD<\/a><\/li>\n<li><a href=\"#faq\">Perguntas frequentes<\/a><\/li>\n<li><a href=\"#references\">Refer\u00eancias e fontes<\/a><\/li>\n<\/ol>\n<\/nav>\n<section id=\"h2-1\">\n<h2>O que \u00e9 uma sa\u00edda OSSD? como os pulsos de teste de canal duplo detectam falhas na fia\u00e7\u00e3o<\/h2>\n<figure style=\"margin:28px 0; text-align:center;\"><img decoding=\"async\" src=\"https:\/\/industrialsafetysensor.com\/wp-content\/uploads\/2026\/11\/ossd-wiring-guide-h2_01.png\" class=\"wp-image-4514\" width=\"1200\" height=\"800\" loading=\"lazy\" style=\"max-width:100%; height:auto; border-radius:8px;\" alt=\"Ilustra pulsos de teste escuros escalonados em OSSD1 e OSSD2 acima da janela do filtro de entrada de seguran\u00e7a downstream.\" \/><\/figure>\n<p>Um Dispositivo de Comuta\u00e7\u00e3o de Sinal de Sa\u00edda (OSSD) \u00e9 o circuito de comuta\u00e7\u00e3o de estado s\u00f3lido dentro de uma cortina de luz de seguran\u00e7a, scanner a laser ou interruptor de intertravamento. Ele usa dois canais semicondutores redundantes (OSSD1 e OSSD2) que s\u00e3o alimentados a 24 V DC e v\u00e3o para 0 V quando uma zona de prote\u00e7\u00e3o \u00e9 violada.<\/p>\n<p>O que significa OSSD na seguran\u00e7a da m\u00e1quina? a abreviatura OSSD define um par de canais de estado s\u00f3lido de eletr\u00f4nica. Dois canais OSSD funcionam em paralelo, assim, uma \u00fanica falha de hardware n\u00e3o pode derrotar a fun\u00e7\u00e3o de seguran\u00e7a. Sob <a href=\"https:\/\/standards.iteh.ai\/catalog\/standards\/clc\/b77ec184-b687-47c0-b4fd-874dc25d41b8\/en-iec-61496-1-2020\" target=\"_blank\" rel=\"noopener\">PT IEC 61496-1:2020 Cl\u00e1usula 4.2.4 e Cl\u00e1usula 5.2.8<\/a>, o equipamento de prote\u00e7\u00e3o eletro-sens\u00edvel (ESPE) deve detectar cada falha el\u00e9trica de ponto \u00fanico automaticamente. As sa\u00eddas de comuta\u00e7\u00e3o padr\u00e3o de 24 V n\u00e3o podem detectar um fio de sinal comprimido contra um condutor de +24 V em uma bandeja. Se esse curto-circuito acontecer em um sensor de n\u00e3o seguran\u00e7a, o controlador l\u00f3gico program\u00e1vel l\u00ea um sinal HIGH permanente. Mesmo que um operador entre na zona de prensa perigosa, a m\u00e1quina continua a opera\u00e7\u00e3o.<\/p>\n<p>Para evitar esta causa de falha, os componentes de seguran\u00e7a OSSD implantam dois canais independentes rotulados OSSD1 e OSSD2. Cada canal usa sua pr\u00f3pria unidade central de processamento ou uma porta l\u00f3gica comparadora para auto-monitorar o estado de sa\u00edda. Se o campo de vis\u00e3o estiver claro, tanto OSSD1 quanto OSSD2 fornecem 24 V DC ao controlador de seguran\u00e7a. Se algo quebrar o feixe ou se perder energia, ambos os canais OSSD v\u00e3o para 0 V.<\/p>\n<h3 id=\"h3-q1\">Como os controladores de seguran\u00e7a testam a integridade do fio sem parar a m\u00e1quina?<\/h3>\n<p>Os sensores de seguran\u00e7a testam a integridade do fio durante a produ\u00e7\u00e3o ativa, injetando breves pulsos de teste escuros de 0 V nas linhas OSSD de 24 V. De acordo com <a href=\"https:\/\/industrialmonitordirect.com\/blogs\/knowledgebase\/how-ossd-safety-outputs-work-electrical-operation-explained\" target=\"_blank\" rel=\"noopener\">dados industriais da opera\u00e7\u00e3o el\u00e9trica OSSD<\/a>, estes pulsos de teste ocorrem em intervalos de 0,5 ms a 10 ms ou at\u00e9 200 ms. Os rel\u00e9s de seguran\u00e7a e controladores de seguran\u00e7a a jusante usam filtros de entrada de 10-20 ms, portanto, mergulhos de 0 V sub-milissegundo nunca desarmar a m\u00e1quina.<\/p>\n<p>Durante cada fase de teste, o microcontrolador embutido do sensor abre um transistor de lado alto por uma fra\u00e7\u00e3o de milissegundo. Em seguida, l\u00ea a tens\u00e3o do pino de sa\u00edda atrav\u00e9s de um loop de feedback interno. Como mostrado em <a href=\"https:\/\/forum.digikey.com\/t\/ossd-safety-signals-what-the-waveform-tells-a-safety-relay\/57545\" target=\"_blank\" rel=\"noopener\">An\u00e1lise de forma de onda do oscilosc\u00f3pio da DigiKey de cortinas de luz SICK e Banner<\/a>, cada sinal permanece ativo alto a 24 VDC. mergulha a 0 VDC uma vez a cada 200 ms. Os dois canais est\u00e3o fora de fase com um per\u00edodo de batimento card\u00edaco de 100 ms entre OSSD1 e OSSD2.<\/p>\n<p>Como o OSSD1 e o OSSD2 pulsam em instantes escalonados, o comparador de realimenta\u00e7\u00e3o integrado detecta qualquer curto-circuito entre fios imediatamente. Suponha que o OSSD1 entre em curto com o OSSD2 dentro de um cabo esmagado. O pulso de teste do OSSD1 passa ent\u00e3o para o OSSD2 no milissegundo errado. Ambos os canais travam imediatamente em um estado de falha de 0 V e cortam a alimenta\u00e7\u00e3o dos atuadores da m\u00e1quina.<\/p>\n<figure class=\"ecc-diagram\" aria-label=\"Forma de onda de temporiza\u00e7\u00e3o de pulso de teste OSSD de canal duplo\">\n<svg viewbox=\"0 0 760 280\" width=\"100%\" height=\"auto\" role=\"img\" aria-labelledby=\"svg-ossd-waveform-title\">\n<title id=\"svg-ossd-waveform-title\">Forma de onda de canal duplo OSSD1 e OSSD2 de 24 VDC com pulsos de teste escuros de 0 VDC fora de fase<\/title>\n<rect x=\"0\" y=\"0\" width=\"760\" height=\"280\" fill=\"#F0F0F0\" rx=\"6\" stroke=\"#303030\" stroke-width=\"1.5\"\/>\n<text x=\"20\" y=\"28\" font-family=\"Arial, sans-serif\" font-size=\"14\" font-weight=\"bold\" fill=\"#181818\">Pulsos de teste escuros escalonados OSSD1 e OSSD2 versus janela de filtro de entrada de seguran\u00e7a (10-20 ms)<\/text>\n<line x1=\"80\" y1=\"50\" x2=\"720\" y2=\"50\" stroke=\"#cccccc\" stroke-dasharray=\"4,4\"\/>\n<line x1=\"80\" y1=\"100\" x2=\"720\" y2=\"100\" stroke=\"#cccccc\" stroke-dasharray=\"4,4\"\/>\n<line x1=\"80\" y1=\"150\" x2=\"720\" y2=\"150\" stroke=\"#cccccc\" stroke-dasharray=\"4,4\"\/>\n<line x1=\"80\" y1=\"200\" x2=\"720\" y2=\"200\" stroke=\"#cccccc\" stroke-dasharray=\"4,4\"\/>\n<text x=\"15\" y=\"55\" font-family=\"Arial, sans-serif\" font-size=\"12\" font-weight=\"bold\" fill=\"#303030\">OSSD1 (24V)<\/text>\n<text x=\"15\" y=\"103\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#484848\">0 VDC<\/text>\n<text x=\"15\" y=\"155\" font-family=\"Arial, sans-serif\" font-size=\"12\" font-weight=\"bold\" fill=\"#303030\">OSSD2 (24V)<\/text>\n<text x=\"15\" y=\"203\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#484848\">0 VDC<\/text>\n<polyline fill=\"none\" stroke=\"#181818\" stroke-width=\"2.5\" points=\"80,55 180,55 180,98 194,98 194,55 420,55 420,98 434,98 434,55 680,55\"\/>\n<polyline fill=\"none\" stroke=\"#484848\" stroke-width=\"2.5\" points=\"80,155 300,155 300,198 314,198 314,155 540,155 540,198 554,198 554,155 680,155\"\/>\n<text x=\"165\" y=\"118\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#181818\">T1: 150 us 1 ms<\/text>\n<text x=\"205\" y=\"44\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#303030\">Deslocamento do batimento card\u00edaco: ~100 ms | Per\u00edodo por canal T2: ~200 ms<\/text>\n<rect x=\"80\" y=\"225\" width=\"600\" height=\"34\" fill=\"#ffffff\" stroke=\"#303030\" stroke-width=\"1\"\/>\n<text x=\"95\" y=\"246\" font-family=\"Arial, sans-serif\" font-size=\"12\" fill=\"#181818\">Rel\u00e9 de seguran\u00e7a a jusante \/filtro de entrada PLC de seguran\u00e7a (10-20 ms) = Alto l\u00f3gico cont\u00ednuo (1)<\/text>\n<\/svg><figcaption>Figura 1: Os pulsos de teste escuros OSSD1 e OSSD2 fora de fase caem para 0 VDC por 150 us a 1 ms a cada 100 ms a 200 ms, permanecendo invis\u00edveis para o filtro de entrada de seguran\u00e7a de 10-20 ms.<\/figcaption><\/figure>\n<p>Resumimos o comportamento exato da forma de onda para estados normais e falhados no <strong>Matriz de diagn\u00f3stico de pulso OSSD de 4 falhas<\/strong> abaixo.<\/p>\n<div class=\"table-responsive\">\n<div class=\"ecc-table-scroll\" style=\"overflow-x:auto;\">\n<table>\n<caption>Tabela 1: Matriz de diagn\u00f3stico de pulso OSSD de 4 falhas (EN IEC 61496-1 Cl\u00e1usula 4.2.4 e Cl\u00e1usula 5.2.8)<\/caption>\n<thead>\n<tr>\n<th>Estado da fia\u00e7\u00e3o\/modo de falha<\/th>\n<th>Forma de onda OSSD1<\/th>\n<th>Forma de onda OSSD2<\/th>\n<th>Comparador interno e a\u00e7\u00e3o do controlador de seguran\u00e7a<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Estado Seguro Normal (Feixe Limpo)<\/strong><\/td>\n<td>24 VDC com pulso de 0 VDC a cada 200 ms<\/td>\n<td>24 VDC com pulso de 0 VDC de deslocamento de fase (deslocamento de 100 ms)<\/td>\n<td>Ambos os canais de seguran\u00e7a permanecem FECHADOS; a m\u00e1quina funciona normalmente.<\/td>\n<\/tr>\n<tr>\n<td><strong>Falha 1: Fornecimento curto a +24 VDC<\/strong><\/td>\n<td>Fixado em cont\u00ednuo 24 VDC (0 VDC mergulho ausente)<\/td>\n<td>Gotas para 0 VDC ap\u00f3s o comparador detectar queda ausente<\/td>\n<td>O sensor trava dentro de um ciclo de pulso; o rel\u00e9 de seguran\u00e7a abre.<\/td>\n<\/tr>\n<tr>\n<td><strong>Falha 2: Curto a 0 VDC \/Terra<\/strong><\/td>\n<td>Fixado em 0 VDC cont\u00ednuo<\/td>\n<td>For\u00e7ado a 0 VDC por l\u00f3gica interna de canal duplo<\/td>\n<td>Controlador de seguran\u00e7a detecta discrep\u00e2ncia ou estado duplo-baixo; m\u00e1quina p\u00e1ra.<\/td>\n<\/tr>\n<tr>\n<td><strong>Falha 3: OSSD1 com abrevia\u00e7\u00e3o cruzada para OSSD2<\/strong><\/td>\n<td>Mostra ambos os pulsos de teste OSSD1 e OSSD2<\/td>\n<td>Mostra sangramento de pulso s\u00edncrono atrav\u00e9s dos canais<\/td>\n<td>O comparador de fase detecta conversa cruzada; ambas as sa\u00eddas travam OFF a 0 VDC.<\/td>\n<\/tr>\n<tr>\n<td><strong>Falha 4: Circuito Aberto\/Fio Cortado<\/strong><\/td>\n<td>0 VDC no terminal de entrada de seguran\u00e7a a jusante<\/td>\n<td>24 VDC no sensor, puxado para 0 VDC em caso de falha<\/td>\n<td>A entrada downstream cai imediatamente; o temporizador de discrep\u00e2ncia bloqueia a reinicializa\u00e7\u00e3o.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"h2-2\">\n<h2>C\u00f3digos de cores padr\u00e3o OSSD Pinagem e fio: conectores M12 de 5 pinos versus 8 pinos<\/h2>\n<figure style=\"margin:28px 0; text-align:center;\"><img decoding=\"async\" src=\"https:\/\/industrialsafetysensor.com\/wp-content\/uploads\/2026\/11\/ossd-wiring-guide-h2_02.png\" class=\"wp-image-4515\" width=\"1200\" height=\"800\" loading=\"lazy\" style=\"max-width:100%; height:auto; border-radius:8px;\" alt=\"Compara layouts de face de conector M12 de 5 pinos e M12 de 8 pinos e prioridade de verifica\u00e7\u00e3o de pinos.\" \/><\/figure>\n<p>Os cabos receptores M12 padr\u00e3o de 5 pinos com codifica\u00e7\u00e3o A conectam o Pino 1 a +24 V (Marrom), o Pino 2 a OSSD1 (Branco) e o Pino 3 a 0 V (Azul). O Pino 4 \u00e9 conectado ao OSSD2 (Preto) e o Pino 5 \u00e9 conectado ao Terra Funcional (Cinza). Os conectores M12 de 8 pinos adicionam Monitoramento de Dispositivos Externos (EDM) e intertravamentos de rearme.<\/p>\n<p>Ao conectar a <a href=\"https:\/\/industrialsafetysensor.com\/pt\/product-category\/safety-light-curtain\/\">cortina luz seguran\u00e7a<\/a>, o emissor e o receptor geralmente n\u00e3o compartilham a mesma contagem de pinos. Apenas a unidade receptora cont\u00e9m os transistores de sa\u00edda OSSD. Conforme documentado em <a href=\"https:\/\/m.dadisick.com\/blog\/How-to-Wire-a-Safety-Light-Curtain-NPN-PNP-Wiring-Diagrams-Common-Issues_b13976\" target=\"_blank\" rel=\"noopener\">guias de fia\u00e7\u00e3o de cortina de luz de seguran\u00e7a industrial<\/a>, pares \u00f3pticos padr\u00e3o usam um Exemplo 2: Emissor com 3 pinos, Receptor com layout de conector de 5 pinos. Os pares de sincroniza\u00e7\u00e3o \u00f3ptica com fio usam um Exemplo 1: Emissor e Receptor com layout de Conectores de 7 pinos.<\/p>\n<p>Independentemente do n\u00famero de pinos do conector, sempre alimentar o sensor a partir de uma fonte dedicada 24 V SELV\/PELV Como a regra de fia\u00e7\u00e3o afirma, use apenas DC 24 V poder nunca conectar energia CA Aplicando 120 V AC poder de controle diretamente para um plugue de sensor M12 ir\u00e1 destruir o est\u00e1gio de sa\u00edda do semicondutor instantaneamente.<\/p>\n<div class=\"table-responsive\">\n<div class=\"ecc-table-scroll\" style=\"overflow-x:auto;\">\n<table>\n<caption>Tabela 2: Pinout padr\u00e3o do conector do receptor M12 de 5 pinos versus 8 pinos e cores de fio IEC 60947-5-2<\/caption>\n<thead>\n<tr>\n<th>Pino M12 #<\/th>\n<th>Cor do fio M12 de 5 pinos (IEC 60947-5-2)<\/th>\n<th>Fun\u00e7\u00e3o Receptora de 5 Pinos<\/th>\n<th>Cor do fio M12 de 8 pinos (IEC 60947-5-2 \/DIN 47100)<\/th>\n<th>Fun\u00e7\u00e3o receptora de 8 pinos<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Pino 1<\/strong><\/td>\n<td>Marrom (BN)<\/td>\n<td>Tens\u00e3o de alimenta\u00e7\u00e3o +24 VDC<\/td>\n<td>Branco (WH) ou Marrom (BN)<\/td>\n<td>OSSD1 ou +24 VDC (ver ficha t\u00e9cnica)<\/td>\n<\/tr>\n<tr>\n<td><strong>Pino 2<\/strong><\/td>\n<td>Branco (WH)<\/td>\n<td>sa\u00edda de seguran\u00e7a OSSD1 1 (PNP de 24 VCC)<\/td>\n<td>Marrom (BN) ou Branco (WH)<\/td>\n<td>Tens\u00e3o de alimenta\u00e7\u00e3o +24 VDC<\/td>\n<\/tr>\n<tr>\n<td><strong>Pino 3<\/strong><\/td>\n<td>Azul (BU)<\/td>\n<td>0 Refer\u00eancia Comum VDC<\/td>\n<td>Verde (GN)<\/td>\n<td>Reiniciar\/Redefinir Intertravamento ou L\u00e2mpada de Silenciamento<\/td>\n<\/tr>\n<tr>\n<td><strong>Pino 4<\/strong><\/td>\n<td>Preto (BK)<\/td>\n<td>sa\u00edda de seguran\u00e7a OSSD2 2 (PNP de 24 VCC)<\/td>\n<td>Amarelo (SIM)<\/td>\n<td>Entrada EDM (Monitoramento de Dispositivos Externos)<\/td>\n<\/tr>\n<tr>\n<td><strong>Pino 5<\/strong><\/td>\n<td>Cinza (GY) ou Verde\/Amarelo<\/td>\n<td>Terra Funcional (FE) \/Sincroniza\u00e7\u00e3o<\/td>\n<td>Cinza (GY)<\/td>\n<td>sa\u00edda de seguran\u00e7a OSSD1 1 (PNP de 24 VCC)<\/td>\n<\/tr>\n<tr>\n<td><strong>Pino 6<\/strong><\/td>\n<td>N\u00e3o Presente<\/td>\n<td>N\/A<\/td>\n<td>Rosa (PK)<\/td>\n<td>sa\u00edda de seguran\u00e7a OSSD2 2 (PNP de 24 VCC)<\/td>\n<\/tr>\n<tr>\n<td><strong>Pino 7<\/strong><\/td>\n<td>N\u00e3o Presente<\/td>\n<td>N\/A<\/td>\n<td>Azul (BU)<\/td>\n<td>0 Refer\u00eancia Comum VDC<\/td>\n<\/tr>\n<tr>\n<td><strong>Pino 8<\/strong><\/td>\n<td>N\u00e3o Presente<\/td>\n<td>N\/A<\/td>\n<td>Vermelho (RD)<\/td>\n<td>Terra Funcional (FE) \/Escudo \/ Auxiliar<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p><strong>Limita\u00e7\u00e3o e cuidado de campo:<\/strong> As cores dos fios nos cabos M12 de extremidade aberta variam entre os cabos IEC 60947-5-2 e os cabos automotivos legados DIN 47100 ou norte-americanos. A verifica\u00e7\u00e3o do n\u00famero do pino na face do conector sempre tem preced\u00eancia sobre a cor do isolamento do fio. Embora as normas IEC padronizem as cores dos sensores de 4 e 5 pinos, os cabos de 8 pinos frequentemente trocam o Marrom e o Branco entre o Pino 1 e o Pino 2.<\/p>\n<p>Combine os n\u00fameros moldados (1 a 5 ou 1 a 8) estampados na face de inser\u00e7\u00e3o M12 com o esquema terminal do seu <a href=\"https:\/\/industrialsafetysensor.com\/pt\/product-category\/multi-beam-safety-sensor\/\">sensor de seguran\u00e7a multifeixe<\/a> ou receptor de cortina de luz, antes de f\u00e9rrulas de crimpagem em cabos abertos. Tamb\u00e9m ligue a prote\u00e7\u00e3o do cabo ao aterramento do gabinete para aliviar a interfer\u00eancia eletromagn\u00e9tica.<\/p>\n<\/section>\n<section id=\"h2-3\">\n<h2>PNP Sourcing vs. NPN Sinking OSSD Wiring: Regras de polaridade e refer\u00eancia comum de 0V<\/h2>\n<figure style=\"margin:28px 0; text-align:center;\"><img decoding=\"async\" src=\"https:\/\/industrialsafetysensor.com\/wp-content\/uploads\/2026\/11\/ossd-wiring-guide-h2_03.png\" class=\"wp-image-4516\" width=\"1200\" height=\"800\" loading=\"lazy\" style=\"max-width:100%; height:auto; border-radius:8px;\" alt=\"Compara a topologia de fornecimento de PNP de alto lado e o comportamento de falha no solo de afundamento de NPN de baixo lado.\" \/><\/figure>\n<p>Os produtos de seguran\u00e7a modernos EN IEC 61496-1 Tipo 4 exigem sa\u00eddas OSSD de fonte dupla PNP, porque os transistores PNP alternam o trilho Positivo de 24 V. Se um fio danificado tocar uma m\u00e1quina de a\u00e7o aterrada, uma sa\u00edda PNP falha com seguran\u00e7a para 0 V e interrompe a m\u00e1quina. As sa\u00eddas de afundamento legadas NPN alternam o caminho de 0 V, de modo que uma falha de aterramento do chassi pode imitar um sinal ON ativo.<\/p>\n<p>A polaridade regula o comportamento da falha por v\u00e1rios motivos. Por exemplo, vamos olhar para as tens\u00f5es terminais para cada estado. Conforme definido no <a href=\"https:\/\/industrialmonitordirect.com\/blogs\/knowledgebase\/how-ossd-safety-outputs-work-electrical-operation-explained\" target=\"_blank\" rel=\"noopener\">especifica\u00e7\u00f5es de opera\u00e7\u00e3o el\u00e9trica OSSD industrial<\/a>, quando o dispositivo de seguran\u00e7a est\u00e1 no estado SAFE, as sa\u00eddas OSSD s\u00e3o energizadas a 24 V. Quando o dispositivo de seguran\u00e7a detecta uma intrus\u00e3o ou falha, ele desenergiza ambas as sa\u00eddas para 0 V.<\/p>\n<p>Em um circuito de fonte PNP, os terminais de entrada do controlador de seguran\u00e7a (S12 e S22) atuam como cargas de afundamento de corrente referenciadas a 0 V. Em contraste, uma sa\u00edda de afundamento NPN puxa uma carga pr\u00e9-energizada para baixo para 0 V quando ativa sob <a href=\"https:\/\/www.osha.gov\/laws-regs\/regulations\/standardnumber\/1910\/1910.217\" target=\"_blank\" rel=\"noopener\">OSHA 29 CFR 1910.217(b)(8)(v)<\/a> e IEC 60204-1, os sistemas de controle industriais usam um secund\u00e1rio PELV aterrado de 0 V. Eles devem evitar que qualquer falha de aterramento \u00fanica cause opera\u00e7\u00e3o falsa da m\u00e1quina.<\/p>\n<p>Se um fio NPN sofrer abras\u00e3o contra uma estrutura de prensa aterrada, essa conex\u00e3o de aterramento completa o caminho de dreno de 0 V permanentemente. Um OSSD fonte PNP em curto com a estrutura aterrada cai para 0 V imediatamente. O limitador de corrente interno atua e ambos os canais bloqueiam com seguran\u00e7a.<\/p>\n<p>Os circuitos PNP OSSD modernos tamb\u00e9m usam comparadores internos de m\u00faltiplas tens\u00f5es para capturar shorts cruzados instantaneamente. De acordo com <a href=\"https:\/\/patents.google.com\/patent\/EP3358592B1\/en\" target=\"_blank\" rel=\"noopener\">Patente Europeia EP3358592B1<\/a>, a tens\u00e3o de alimenta\u00e7\u00e3o fica em 24 V. Enquanto isso, os redutores internos diminuem a tens\u00e3o do primeiro canal para 23 V e a tens\u00e3o do segundo canal para 22 V. Os transistores comparadores PNP acoplados cruzados monitoram continuamente esse diferencial de 1 V. Se qualquer um dos terminais se encurtar para o trilho de alimenta\u00e7\u00e3o de 24 V, o comparador detecta o salto de tens\u00e3o e abre ambos os interruptores para 0 V.<\/p>\n<div class=\"table-responsive\">\n<div class=\"ecc-table-scroll\" style=\"overflow-x:auto;\">\n<table>\n<caption>Tabela 3: Compara\u00e7\u00e3o de polaridade PNP Sourcing vs. NPN Sinking OSSD<\/caption>\n<thead>\n<tr>\n<th>Par\u00e2metro El\u00e9trico<\/th>\n<th>PNP Sourcing OSSD (Padr\u00e3o da Ind\u00fastria)<\/th>\n<th>Sa\u00edda de afundamento de NPN (legado\/n\u00e3o seguran\u00e7a)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Trocando a Topologia do Transistor<\/strong><\/td>\n<td>Transistor MOSFET\/PNP de canal P de lado alto<\/td>\n<td>Transistor MOSFET\/NPN de canal N de baixo lado<\/td>\n<\/tr>\n<tr>\n<td><strong>Tens\u00e3o terminal do estado seguro (limpa)<\/strong><\/td>\n<td>24 V DC ativamente obtido em OSSD1 e OSSD2<\/td>\n<td>Deslizado para baixo a 0 V DC (atual afundando no ch\u00e3o)<\/td>\n<\/tr>\n<tr>\n<td><strong>Tens\u00e3o de estado desarmado (interrompida)<\/strong><\/td>\n<td>0 V DC (alta imped\u00e2ncia puxada para baixo pela carga de entrada)<\/td>\n<td>Flutua alto em dire\u00e7\u00e3o a +24 V DC via pull-up de carga<\/td>\n<\/tr>\n<tr>\n<td><strong>Resultado de falha de aterramento fio-chassi<\/strong><\/td>\n<td>Fails seguro (fixado a 0 V DC; paradas da m\u00e1quina)<\/td>\n<td>Falta insegura (imita o estado 0 V ON ativo)<\/td>\n<\/tr>\n<tr>\n<td><strong>Rel\u00e9 de seguran\u00e7a\/compatibilidade com PLC de seguran\u00e7a<\/strong><\/td>\n<td>Diretamente compat\u00edvel com entradas IEC 61496-1 Tipo 4<\/td>\n<td>Incompat\u00edvel com m\u00f3dulos F-DI de comuta\u00e7\u00e3o positiva<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p>Nunca combine sa\u00eddas PNP e NPN no mesmo rel\u00e9 de seguran\u00e7a. Nunca conecte um resistor externo pull-up ou pull-down a uma linha OSSD para inverter sua l\u00f3gica. Al\u00e9m disso, a fonte de 24 V DC alimentando o sensor e a fonte de 24 V DC alimentando o controlador de seguran\u00e7a devem compartilhar um terminal de refer\u00eancia comum de 0 V ligado. Sem um barramento de refer\u00eancia compartilhado de 0 V, os sinais OSSD de 24 V n\u00e3o t\u00eam caminho de retorno e as entradas de seguran\u00e7a falhar\u00e3o.<\/p>\n<\/section>\n<section id=\"h2-4\">\n<h2>Como conectar OSSD1 e OSSD2 a um rel\u00e9 de seguran\u00e7a com EDM e redefinir feedback<\/h2>\n<figure style=\"margin:28px 0; text-align:center;\"><img decoding=\"async\" src=\"https:\/\/industrialsafetysensor.com\/wp-content\/uploads\/2026\/11\/ossd-wiring-guide-h2_04.png\" class=\"wp-image-4517\" width=\"1200\" height=\"800\" loading=\"lazy\" style=\"max-width:100%; height:auto; border-radius:8px;\" alt=\"Mostra os terminais de rel\u00e9 de seguran\u00e7a de alimenta\u00e7\u00e3o OSSD1 e OSSD2 S12 e S22 ao lado do feedback EDM da s\u00e9rie e do loop de reinicializa\u00e7\u00e3o manual.\" \/><\/figure>\n<p>Para conectar um sensor OSSD de canal duplo a um rel\u00e9 de seguran\u00e7a, aterre OSSD1 na entrada de seguran\u00e7a S12 e OSSD2 na entrada de seguran\u00e7a S22. ligue ambos os bens comuns de 0 V juntos no terminal A2. deixe os terminais de pulso de teste internos do rel\u00e9 de seguran\u00e7a (S11 e S21) desconectados, porque o sensor OSSD fornece seus pr\u00f3prios pulsos de teste de energia e escuro de 24 V.<\/p>\n<p>Como mostrado em <a href=\"https:\/\/forum.digikey.com\/t\/ossd-safety-signals-what-the-waveform-tells-a-safety-relay\/57545\" target=\"_blank\" rel=\"noopener\">Avalia\u00e7\u00e3o da DigiKey do m\u00f3dulo de seguran\u00e7a Schneider Electric XPSBAT12A1AC<\/a>, um rel\u00e9 de seguran\u00e7a compat\u00edvel com OSSD atinge PL e e Categoria 4 sob a norma ISO 13849-1. Ele tamb\u00e9m atinge uma classifica\u00e7\u00e3o de confiabilidade de componentes de MTTFd &gt; 30 anos. Alcan\u00e7ar esse n\u00edvel EN ISO 13849-1 Categoria 4 requer Monitoramento de Dispositivos Externos (EDM). O loop EDM comprova que os contatores a jusante K1 e K2 abrem fisicamente em cada comando de parada.<\/p>\n<p>Em prensas mec\u00e2nicas, o monitoramento do desempenho de parada tamb\u00e9m \u00e9 uma regra obrigat\u00f3ria de seguran\u00e7a e sa\u00fade ocupacional. Sob <a href=\"https:\/\/www.osha.gov\/laws-regs\/regulations\/standardnumber\/1910\/1910.217\" target=\"_blank\" rel=\"noopener\">OSHA 29 CFR 1910.217(h)(5)(ii)<\/a>, o monitor de freio permite um aumento de tempo de parada de no m\u00e1ximo 10 por cento, ou 10 milissegundos, o que for mais longo A fia\u00e7\u00e3o dos contatos auxiliares NC mecanicamente ligados de K1 e K2 no loop EDM, evita um novo curso de prensa se um contator principal solda fechada.<\/p>\n<figure class=\"ecc-diagram\" aria-label=\"ESQUEMA de feedback do contator OSSD para rel\u00e9 de seguran\u00e7a e EDM\">\n<svg viewbox=\"0 0 760 310\" width=\"100%\" height=\"auto\" role=\"img\" aria-labelledby=\"svg-edm-wiring-title\">\n<title id=\"svg-edm-wiring-title\">Esquem\u00e1tico de fia\u00e7\u00e3o de rel\u00e9 de seguran\u00e7a OSSD1 e OSSD2 para canal duplo com loop de feedback K1\/K2 EDM<\/title>\n<rect x=\"0\" y=\"0\" width=\"760\" height=\"310\" fill=\"#F0F0F0\" rx=\"6\" stroke=\"#303030\" stroke-width=\"1.5\"\/>\n<text x=\"20\" y=\"26\" font-family=\"Arial, sans-serif\" font-size=\"14\" font-weight=\"bold\" fill=\"#181818\">Categoria 4 \/Fia\u00e7\u00e3o PL e: Receptor OSSD para Rel\u00e9 de Seguran\u00e7a com Feedback K1\/K2 EDM<\/text>\n<rect x=\"25\" y=\"55\" width=\"190\" height=\"220\" fill=\"#ffffff\" stroke=\"#181818\" stroke-width=\"2\" rx=\"4\"\/>\n<text x=\"40\" y=\"80\" font-family=\"Arial, sans-serif\" font-size=\"13\" font-weight=\"bold\" fill=\"#181818\">Receptor de seguran\u00e7a OSSD<\/text>\n<text x=\"40\" y=\"110\" font-family=\"Arial, sans-serif\" font-size=\"12\" fill=\"#303030\">Pino 1 (BN): +24 VCC<\/text>\n<text x=\"40\" y=\"150\" font-family=\"Arial, sans-serif\" font-size=\"12\" font-weight=\"bold\" fill=\"#181818\">Pino 2 (WH): OSSD1<\/text>\n<text x=\"40\" y=\"190\" font-family=\"Arial, sans-serif\" font-size=\"12\" font-weight=\"bold\" fill=\"#181818\">Pino 4 (BK): OSSD2<\/text>\n<text x=\"40\" y=\"230\" font-family=\"Arial, sans-serif\" font-size=\"12\" fill=\"#303030\">Pino 3 (BU): 0 VCC<\/text>\n<text x=\"40\" y=\"260\" font-family=\"Arial, sans-serif\" font-size=\"12\" fill=\"#484848\">Pino 5 (GY): Escudo FE<\/text>\n<rect x=\"305\" y=\"55\" width=\"210\" height=\"220\" fill=\"#ffffff\" stroke=\"#181818\" stroke-width=\"2\" rx=\"4\"\/>\n<text x=\"320\" y=\"80\" font-family=\"Arial, sans-serif\" font-size=\"13\" font-weight=\"bold\" fill=\"#181818\">M\u00f3dulo Rel\u00e9 Seguran\u00e7a<\/text>\n<text x=\"320\" y=\"110\" font-family=\"Arial, sans-serif\" font-size=\"12\" fill=\"#303030\">A1: +24 VCC | S11\/S21: NC<\/text>\n<text x=\"320\" y=\"150\" font-family=\"Arial, sans-serif\" font-size=\"12\" font-weight=\"bold\" fill=\"#181818\">S12: Entrada Segura Ch 1<\/text>\n<text x=\"320\" y=\"190\" font-family=\"Arial, sans-serif\" font-size=\"12\" font-weight=\"bold\" fill=\"#181818\">S22: Entrada Segura Ch 2<\/text>\n<text x=\"320\" y=\"230\" font-family=\"Arial, sans-serif\" font-size=\"12\" fill=\"#303030\">A2: 0 VDC Comum<\/text>\n<text x=\"320\" y=\"260\" font-family=\"Arial, sans-serif\" font-size=\"12\" font-weight=\"bold\" fill=\"#303030\">S33-S34: EDM e redefini\u00e7\u00e3o<\/text>\n<line x1=\"215\" y1=\"146\" x2=\"305\" y2=\"146\" stroke=\"#181818\" stroke-width=\"2.5\"\/>\n<line x1=\"215\" y1=\"186\" x2=\"305\" y2=\"186\" stroke=\"#484848\" stroke-width=\"2.5\"\/>\n<line x1=\"215\" y1=\"226\" x2=\"305\" y2=\"226\" stroke=\"#303030\" stroke-width=\"1.8\" stroke-dasharray=\"5,3\"\/>\n<rect x=\"570\" y=\"55\" width=\"165\" height=\"220\" fill=\"#ffffff\" stroke=\"#303030\" stroke-width=\"2\" rx=\"4\"\/>\n<text x=\"585\" y=\"80\" font-family=\"Arial, sans-serif\" font-size=\"13\" font-weight=\"bold\" fill=\"#181818\">EDM e contatores<\/text>\n<text x=\"585\" y=\"115\" font-family=\"Arial, sans-serif\" font-size=\"12\" fill=\"#181818\">13-14 -&gt; Bobina K1<\/text>\n<text x=\"585\" y=\"145\" font-family=\"Arial, sans-serif\" font-size=\"12\" fill=\"#181818\">23-24 -&gt; Bobina K2<\/text>\n<text x=\"585\" y=\"190\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#303030\">S33 -&gt; K1(NC) -&gt; K2(NC)<\/text>\n<text x=\"585\" y=\"215\" font-family=\"Arial, sans-serif\" font-size=\"11\" fill=\"#303030\">-&gt; Redefinir PB -&gt; S34<\/text>\n<text x=\"585\" y=\"250\" font-family=\"Arial, sans-serif\" font-size=\"11\" font-weight=\"bold\" fill=\"#181818\">ISO 13849-1 Gato 4 \/PL e<\/text>\n<line x1=\"515\" y1=\"120\" x2=\"570\" y2=\"120\" stroke=\"#181818\" stroke-width=\"2\"\/>\n<line x1=\"515\" y1=\"255\" x2=\"570\" y2=\"205\" stroke=\"#303030\" stroke-width=\"2\"\/>\n<\/svg><figcaption>Figura 2: Fia\u00e7\u00e3o direta OSSD1 (S12) e OSSD2 (S22) para um rel\u00e9 de seguran\u00e7a com contatos auxiliares K1 e K2 NC guiados por for\u00e7a conectados em s\u00e9rie com o EDM S33-S34 e o loop de reinicializa\u00e7\u00e3o.<\/figcaption><\/figure>\n<p>Consulte o <strong>Verifica\u00e7\u00e3o do loop de feedback do contator EDM de 3 pontos<\/strong> abaixo, antes de energizar o rel\u00e9 de seguran\u00e7a:<\/p>\n<ol>\n<li>Primeiro, selecione os contatores K1 e K2 com contatos de espelho NC ligados mecanicamente (terminais 21-22) sob IEC 60947-4-1 Anexo F para que os contatos auxiliares n\u00e3o possam fechar se algum p\u00f3lo de pot\u00eancia principal for fechado.<\/li>\n<li>Em segundo lugar, o terminal de rota S33 em s\u00e9rie com o contato K1 NC, o contato K2 NC e um bot\u00e3o de reinicializa\u00e7\u00e3o manual para o terminal S34. use o EDM interno de um sensor de 8 pinos e trace +24 V atrav\u00e9s de K1 NC e K2 NC para o Pin 4.<\/li>\n<li>Terceiro, me\u00e7a a resist\u00eancia da corrente da s\u00e9rie K1 NC-K2 NC com um ohm\u00edmetro quando a corrente \u00e9 desenergizada A resist\u00eancia do la\u00e7o deve ficar abaixo de 2 ohms quando aberta, e o circuito deve quebrar dentro de 20 ms quando K1 e K2 puxam.<\/li>\n<\/ol>\n<h3 id=\"h3-q2\">Como reiniciar um sistema ap\u00f3s uma falha OSSD versus uma quebra tempor\u00e1ria do feixe?<\/h3>\n<p>Reiniciar ap\u00f3s uma quebra tempor\u00e1ria do feixe requer limpar o campo de detec\u00e7\u00e3o e pressionar o bot\u00e3o de reinicializa\u00e7\u00e3o manual assim que OSSD1 e OSSD2 retornarem a 24 V. O rel\u00e9 de seguran\u00e7a procura uma transi\u00e7\u00e3o de 0 V para 24 V para 0 V na borda de fuga no S34 para que um operador n\u00e3o possa adulterar o bot\u00e3o gravando-o Em contraste, limpar uma falha OSSD cross-short requer a fixa\u00e7\u00e3o do cabo danificado e ligar a fonte de alimenta\u00e7\u00e3o de 24 V DC.<\/p>\n<p>Quando a zona de perigo \u00e9 grande, e uma pessoa pode passar pelo campo de detec\u00e7\u00e3o e entrar na zona de perigo, o rel\u00e9 de seguran\u00e7a n\u00e3o deve ser automaticamente reiniciado. Se for esse o caso, de acordo com EN IEC 61496-1 Anexo A.8, o interruptor de reinicializa\u00e7\u00e3o manual deve ser colocado fora da zona de perigo e \u00e0 vista da \u00e1rea protegida.<\/p>\n<\/section>\n<section id=\"h2-5\">\n<h2>Conectando sa\u00eddas OSSD a um PLC de seguran\u00e7a ou controlador de seguran\u00e7a: configura\u00e7\u00f5es de pulso de teste e discrep\u00e2ncia<\/h2>\n<figure style=\"margin:28px 0; text-align:center;\"><img decoding=\"async\" src=\"https:\/\/industrialsafetysensor.com\/wp-content\/uploads\/2026\/11\/ossd-wiring-guide-h2_05.png\" class=\"wp-image-4518\" width=\"1200\" height=\"800\" loading=\"lazy\" style=\"max-width:100%; height:auto; border-radius:8px;\" alt=\"Resume as quatro configura\u00e7\u00f5es principais de hardware Safety PLC F-DI necess\u00e1rias para entradas OSSD.\" \/><\/figure>\n<p>Ao conectar as sa\u00eddas OSSD \u00e0 placa F-DI de um PLC de Seguran\u00e7a ou a uma entrada STO de acionamento seguro, desative os pulsos de teste do PLC. Deixar os pulsos de teste ligados causa colis\u00f5es de pulso com os pulsos escuros OSSD do sensor, o que resulta em bloqueios falsos de canal.<\/p>\n<p>Conforme declarado no <a href=\"https:\/\/www.blog.beckhoffus.com\/post\/test-pulses-vs-ossd\" target=\"_blank\" rel=\"noopener\">Nota de aplica\u00e7\u00e3o TwinSAFE EL1918 e EL1904 de Beckhoff<\/a>, as entradas de seguran\u00e7a padr\u00e3o emparelham cada entrada com uma sa\u00edda com clock fornecendo um +24 V pulsado. Esse pulso testa contatos mec\u00e2nicos secos para curtos-circuitos. Uma vez que um sensor OSSD auto-teste j\u00e1 gera seu pr\u00f3prio sinal de 24 V e pulsos de teste peri\u00f3dicos de 0 V, permitindo que o pulso de clock do PLC crie colis\u00f5es ass\u00edncronas de forma de onda.<\/p>\n<p>Unidades de movimento seguro e controladores de seguran\u00e7a especificam janelas de tempo estritas para entradas OSSD. De acordo com o <a href=\"https:\/\/webhelp.kollmorgen.com\/akd2g\/english\/content\/akd2g-s%20install\/e\/fsm\/AKD2S_install_20_06_OSSD.htm\" target=\"_blank\" rel=\"noopener\">Manual de instala\u00e7\u00e3o da unidade de seguran\u00e7a Kollmorgen AKD2G<\/a>, entradas digitais seguras SIN1 para SIN4 aceitam larguras de pulso T1 de 150 us para 1 ms. O per\u00edodo de pulso necess\u00e1rio T2 abrange de 100 ms a 1 s com canais n\u00e3o sobrepostos Enquanto isso, os pulsos de teste em sa\u00eddas digitais seguras (SOUT1 a SOUT4) correm em T1 450 us para 550 us e T2 810 ms para 990 ms.<\/p>\n<p><strong>Regra de Limita\u00e7\u00e3o e Configura\u00e7\u00e3o<\/strong>: Habilitar o gerador de pulsos de teste de rel\u00f3gio interno do PLC de seguran\u00e7a em um canal F-DI conectado a um sensor OSSD leva a colis\u00f5es de pulso e falhas inc\u00f4modas. No Portal Siemens TIA (ET 200 SP F-DI), Allen-Bradley Studio 5000 (GuardLogix) ou Beckhoff TwinSAFE, defina a fonte do sensor para \u201cExternal. Em seguida, desative os pulsos de teste de curto-circuito em ambos os canais de entrada.<\/p>\n<p>Usar o <strong>Rel\u00e9 de seguran\u00e7a em 5 etapas versus seletor de interface F-DI<\/strong> abaixo para definir corretamente os par\u00e2metros do seu controlador de seguran\u00e7a:<\/p>\n<div class=\"table-responsive\">\n<div class=\"ecc-table-scroll\" style=\"overflow-x:auto;\">\n<table>\n<caption>Tabela 4: Rel\u00e9 de seguran\u00e7a em 5 etapas versus seletor de configura\u00e7\u00e3o de par\u00e2metro F-DI de seguran\u00e7a PLC<\/caption>\n<thead>\n<tr>\n<th>Passo Configura\u00e7\u00e3o<\/th>\n<th>M\u00f3dulo de rel\u00e9 de seguran\u00e7a dedicado<\/th>\n<th>Entrada digital segura contra falhas (F-DI) do PLC de seguran\u00e7a<\/th>\n<th>STO de canal duplo com unidade de movimento seguro<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Passo 1: Fonte de alimenta\u00e7\u00e3o<\/strong><\/td>\n<td>Sensor de alimenta\u00e7\u00e3o OSSD de 24 V DC externo (deixe S11\/S21 aberto)<\/td>\n<td>Selecione \u201cExternal Sensor Supply\u201d na configura\u00e7\u00e3o de hardware<\/td>\n<td>Sensor de alimenta\u00e7\u00e3o do barramento PELV compartilhado de 24V<\/td>\n<\/tr>\n<tr>\n<td><strong>Passo 2: Pulsos de teste internos<\/strong><\/td>\n<td>Desative a detec\u00e7\u00e3o de curto-circuito cruzado por meio de interruptor de imers\u00e3o se alimentado via S12\/S22<\/td>\n<td>Desative as sa\u00eddas de teste com clock PLC (T0\/T1 OFF)<\/td>\n<td>Defina o filtro de entrada STO para aceitar pulsos OSSD de 150 us a 1 ms<\/td>\n<\/tr>\n<tr>\n<td><strong>Etapa 3: Avalia\u00e7\u00e3o do Canal<\/strong><\/td>\n<td>Avalia\u00e7\u00e3o 1oo2 de canal duplo (equivalente \/alto ativo)<\/td>\n<td>1oo2 (2v2) Modo de avalia\u00e7\u00e3o equivalente<\/td>\n<td>Dual-channel STO_A e STO_B simult\u00e2neo alto<\/td>\n<\/tr>\n<tr>\n<td><strong>Passo 4: Tempo de Discrep\u00e2ncia<\/strong><\/td>\n<td>Janela de hardware fixa (50 ms a 500 ms)<\/td>\n<td>Defina o temporizador de discrep\u00e2ncia de software para 50 ms 100 ms<\/td>\n<td>Defina a toler\u00e2ncia \u00e0 discrep\u00e2ncia do canal STO para &lt;= 100 ms<\/td>\n<\/tr>\n<tr>\n<td><strong>Etapa 5: Caminho de feedback EDM<\/strong><\/td>\n<td>Loop K1\/K2 NC conectado ao terminal de reinicializa\u00e7\u00e3o S33-S34<\/td>\n<td>Leia o contato auxiliar K1\/K2 NC no bloco padr\u00e3o DI + F-FB_EDM<\/td>\n<td>Leia a palavra de status STO sobre FSoE\/PROFISafe ou EDM conectado<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"h2-6\">\n<h2>Fia\u00e7\u00e3o OSSD espec\u00edfica do dispositivo: cortinas de luz de seguran\u00e7a versus scanners a laser de seguran\u00e7a<\/h2>\n<figure style=\"margin:28px 0; text-align:center;\"><img decoding=\"async\" src=\"https:\/\/industrialsafetysensor.com\/wp-content\/uploads\/2026\/11\/ossd-wiring-guide-h2_06.png\" class=\"wp-image-4519\" width=\"1200\" height=\"800\" loading=\"lazy\" style=\"max-width:100%; height:auto; border-radius:8px;\" alt=\"Compara as arquiteturas de cabos e conectores de cortinas de luz, scanners a laser, intertravamentos RFID e unidades de avalia\u00e7\u00e3o de tapetes de seguran\u00e7a.\" \/><\/figure>\n<p>Enquanto todos os sensores de seguran\u00e7a eletro-sens\u00edveis emitem sinais duplos PNP OSSD de 24 V, as cortinas de luz de seguran\u00e7a usam cabos emissores e receptores separados com sincroniza\u00e7\u00e3o \u00f3ptica ou de fio. Os dispositivos de varredura a laser, por outro lado, integram o emissor, o receptor, o EDM e a comuta\u00e7\u00e3o de zona din\u00e2mica em um \u00fanico plugue de sistema multi-pin.<\/p>\n<p>Sob <a href=\"https:\/\/standards.iteh.ai\/catalog\/standards\/clc\/b77ec184-b687-47c0-b4fd-874dc25d41b8\/en-iec-61496-1-2020\" target=\"_blank\" rel=\"noopener\">PT IEC 61496-1:2020 e IEC 61496-2:2020<\/a>, os dispositivos de protec\u00e7\u00e3o opto-electr\u00f3nicos activos (AOPDs) operam dentro da banda de comprimento de onda \u00f3ptico de 400 nm a 1 500 nm. aquando da instala\u00e7\u00e3o de um <a href=\"https:\/\/industrialsafetysensor.com\/pt\/product-category\/safety-light-curtain\/\">cortina luz seguran\u00e7a<\/a> em uma prensa el\u00e9trica no modo de inicia\u00e7\u00e3o de dispositivo de detec\u00e7\u00e3o de presen\u00e7a (PSDI), <a href=\"https:\/\/www.osha.gov\/laws-regs\/regulations\/standardnumber\/1910\/1910.217\" target=\"_blank\" rel=\"noopener\">OSHA 29 CFR 1910.217(h)(9)(ii)<\/a> define um limite de resolu\u00e7\u00e3o rigoroso. As cortinas de luz usadas para opera\u00e7\u00e3o PSDI devem ter uma sensibilidade m\u00ednima ao objeto n\u00e3o superior a 31,75 mm (1,25 polegadas).<\/p>\n<p>Al\u00e9m disso, o tempo de resposta do OSSD e o tempo de parada da prensa estabelecem um limite inferior para a dist\u00e2ncia de montagem do sensor. Sob <a href=\"https:\/\/www.osha.gov\/laws-regs\/regulations\/standardnumber\/1910\/1910.217\" target=\"_blank\" rel=\"noopener\">OSHA 29 CFR 1910.217<\/a>, dist\u00e2ncia m\u00ednima de seguran\u00e7a segue a equa\u00e7\u00e3o Ds = Hs * (Ts + Tp + Tr + 2 Tm) + Dp. Nesta f\u00f3rmula, Hs \u00e9 a constante de velocidade da m\u00e3o de 63 polegadas por segundo (1,6 m\/s).Com cada milissegundo adicionado ao tempo de retorno do rel\u00e9 OSSD (Tr), a dist\u00e2ncia de montagem necess\u00e1ria do ponto de aperto aumenta.<\/p>\n<p>Entretanto, a <a href=\"https:\/\/industrialsafetysensor.com\/pt\/product-category\/safety-laser-scanner\/\">scanner laser seguran\u00e7a<\/a> em um AGV usa reflex\u00e3o difusa Tipo 3 (IEC 61496-3).Interclos sem contato de identifica\u00e7\u00e3o por radiofrequ\u00eancia (RFID) e sensores de seguran\u00e7a de radar tamb\u00e9m usam canais OSSD duplos, mas adicionam entradas em cascata ou sa\u00eddas multizonas.<\/p>\n<div class=\"table-responsive\">\n<div class=\"ecc-table-scroll\" style=\"overflow-x:auto;\">\n<table>\n<caption>Tabela 5: Matriz de classifica\u00e7\u00e3o de dispositivos OSSD por tipo de sensor, cen\u00e1rio de aplica\u00e7\u00e3o e arquitetura de pino<\/caption>\n<thead>\n<tr>\n<th>Categoria do dispositivo\/tipo de sensor<\/th>\n<th>Cen\u00e1rio Aplica\u00e7\u00e3o<\/th>\n<th>Padr\u00e3o de seguran\u00e7a aplic\u00e1vel<\/th>\n<th>Especifica\u00e7\u00e3o do conector e canal OSSD<\/th>\n<th>Regra de sele\u00e7\u00e3o de fia\u00e7\u00e3o chave<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Cortina de luz de seguran\u00e7a tipo 4 (dedo\/m\u00e3o)<\/strong><\/td>\n<td>Ponto de opera\u00e7\u00e3o da prensa hidr\u00e1ulica e mec\u00e2nica<\/td>\n<td>IEC 61496-1 e IEC 61496-2 (400 nm a 1 500 nm)<\/td>\n<td>Emissor de 3 pinos + Receptor M12 de 5 pinos ou 8 pinos; 2 x PNP OSSD<\/td>\n<td>Mantenha a sensibilidade &lt;= 31,75 mm para PSDI; la\u00e7o de EDM do fio K1\/K2<\/td>\n<\/tr>\n<tr>\n<td><strong>Cortina de luz de seguran\u00e7a tipo 2 (corpo\/acesso)<\/strong><\/td>\n<td>Acesso perimetral de embalagens e paletizadores de baixo risco<\/td>\n<td>IEC 61496-1 e IEC 61496-2 (PL c\/SIL 1)<\/td>\n<td>Receptor M12 de 5 pinos; OSSD duplo ou OSSD \u00fanico com entrada de teste<\/td>\n<td>Combine a entrada de teste peri\u00f3dica com a sa\u00edda de teste do controlador de seguran\u00e7a<\/td>\n<\/tr>\n<tr>\n<td><strong>Scanner a laser de seguran\u00e7a (c\u00e9lula estacion\u00e1ria)<\/strong><\/td>\n<td>C\u00e9lula de soldagem rob\u00f3tica &amp; prote\u00e7\u00e3o de \u00e1rea de prensa dobradeira<\/td>\n<td>IEC 61496-1 e IEC 61496-3 (Tipo 3\/PL d)<\/td>\n<td>plugue do sistema M12 de 8 ou 12 pinos; 1 par OSSD + 1 aviso de sa\u00edda<\/td>\n<td>Sa\u00edda separada do aviso da n\u00e3o-seguran\u00e7a do par OSSD1\/OSSD2<\/td>\n<\/tr>\n<tr>\n<td><strong>Scanner a laser de seguran\u00e7a (Mobile AGV\/AMR)<\/strong><\/td>\n<td>Evita\u00e7\u00e3o de colis\u00e3o aut\u00f4noma de rob\u00f4s m\u00f3veis<\/td>\n<td>IEC 61496-3 e ISO 3691-4 (PL d)<\/td>\n<td>M12 de 12 pinos ou 17 pinos; 2 x pares OSSD + entradas de campo do codificador<\/td>\n<td>Entradas de codificador de canal duplo complementares de fio para comuta\u00e7\u00e3o de zona<\/td>\n<\/tr>\n<tr>\n<td><strong>Grade de luz de seguran\u00e7a multifeixe (2 a 4 feixes)<\/strong><\/td>\n<td>Guarda de entrada\/sa\u00edda do per\u00edmetro com silenciamento<\/td>\n<td>IEC 61496-2 Tipo 4 (PL e \/SIL 3)<\/td>\n<td>5 pinos ou 8 pinos M12; sensor de silenciamento integrado e pinos de l\u00e2mpada<\/td>\n<td>Monitore a corrente da l\u00e2mpada de silenciamento para evitar o bloqueio de falhas da l\u00e2mpada escura<\/td>\n<\/tr>\n<tr>\n<td><strong>Sensor de seguran\u00e7a fotoel\u00e9trico de feixe \u00fanico<\/strong><\/td>\n<td>Portas de acesso de longo alcance e corredores de armazenamento automatizados<\/td>\n<td>IEC 61496-2 Tipo 2\/Tipo 4<\/td>\n<td>Cabe\u00e7as \u00f3pticas M12 de 4 pinos conectadas \u00e0 unidade de avalia\u00e7\u00e3o de trilho DIN<\/td>\n<td>Termine OSSD1\/OSSD2 no controlador central de avalia\u00e7\u00e3o<\/td>\n<\/tr>\n<tr>\n<td><strong>Interruptor de bloqueio de seguran\u00e7a sem contato RFID<\/strong><\/td>\n<td>Portas articuladas &amp; deslizantes da prote\u00e7\u00e3o da m\u00e1quina (resistente ao adultera\u00e7\u00e3o)<\/td>\n<td>IEC 60947-5-3 e EN ISO 14119 Tipo 4<\/td>\n<td>pigtail M12 de 8 pinos; entradas de seguran\u00e7a duplas (SI1\/SI2) + OSSD duplo<\/td>\n<td>Use atuadores RFID codificados para evitar desvio ou viola\u00e7\u00e3o do operador<\/td>\n<\/tr>\n<tr>\n<td><strong>Tapete\/borda de seguran\u00e7a com unidade de avalia\u00e7\u00e3o OSSD<\/strong><\/td>\n<td>Sensoriamento de presen\u00e7a de piso t\u00e1til em torno de tabelas de indexa\u00e7\u00e3o<\/td>\n<td>ISO 13856-1\/ISO 13856-2<\/td>\n<td>Sensor resistivo de 4 fios no m\u00f3dulo conversor OSSD<\/td>\n<td>Converta o loop de curto-circuito de 4 fios em um par PNP OSSD de 24 V<\/td>\n<\/tr>\n<tr>\n<td><strong>Tempo de voo 3 D\/Sensor de radar seguro<\/strong><\/td>\n<td>M\u00e1quinas pesadas de alta poeira, respingos de solda ou ao ar livre<\/td>\n<td>IEC TS 62998-1 e ISO 13849-1 PL d<\/td>\n<td>8 pinos M12 power\/OSSD + porta de diagn\u00f3stico Ethernet M12 de 4 pinos<\/td>\n<td>Use cabo de par tran\u00e7ado blindado e terra funcional de liga\u00e7\u00e3o<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p>Em c\u00e9lulas h\u00edbridas, os engenheiros frequentemente emparelham a <a href=\"https:\/\/industrialsafetysensor.com\/pt\/product-category\/single-beam-safety-sensor\/\">sensor de seguran\u00e7a de feixe \u00fanico<\/a> ou codificado <a href=\"https:\/\/industrialsafetysensor.com\/pt\/product-category\/safety-switches\/\">interruptores seguran\u00e7a<\/a> em port\u00f5es de acesso com um scanner de \u00e1rea dentro da c\u00e9lula. Em todos os casos, os sinais de aviso auxiliares devem ser roteados em condutores separados das linhas OSSD1 e OSSD2 com classifica\u00e7\u00e3o de seguran\u00e7a.<\/p>\n<\/section>\n<section id=\"h2-7\">\n<h2>Fia\u00e7\u00e3o em s\u00e9rie e dispositivos OSSD m\u00faltiplos em cascata: evitando o mascaramento de falhas sob ISO\/TR 24119<\/h2>\n<figure style=\"margin:28px 0; text-align:center;\"><img decoding=\"async\" src=\"https:\/\/industrialsafetysensor.com\/wp-content\/uploads\/2026\/11\/ossd-wiring-guide-h2_07.png\" class=\"wp-image-4520\" width=\"1200\" height=\"800\" loading=\"lazy\" style=\"max-width:100%; height:auto; border-radius:8px;\" alt=\"Contrasta o mascaramento passivo de falhas em s\u00e9rie com loops de diagn\u00f3stico M12 ativos e fia\u00e7\u00e3o de seguran\u00e7a IO-Link ponto a ponto.\" \/><\/figure>\n<p>Ao contr\u00e1rio dos contatos mec\u00e2nicos secos E-stop, as sa\u00eddas semicondutoras OSSD padr\u00e3o n\u00e3o podem ser conectadas em s\u00e9rie alimentando OSSD1 do sensor A no pino de alimenta\u00e7\u00e3o de +24 V do sensor B. A cascata de v\u00e1rios dispositivos OSSD requer sensores com entradas de seguran\u00e7a duplas dedicadas (SI1 e SI2), um loop de n\u00f3 de diagn\u00f3stico ativo ou entradas de PLC de seguran\u00e7a dedicadas.<\/p>\n<p><strong>Regra de limita\u00e7\u00e3o e ISO 14119:<\/strong> O encadeamento direto de margaridas de sa\u00eddas OSSD padr\u00e3o sem monitoramento de n\u00f3 individual oculta falhas cruzadas de canal \u00fanico (mascaramento de falhas).Esse layout limita a cobertura de diagn\u00f3stico alcan\u00e7\u00e1vel sob ISO\/TR 24119. como mostrado em <a href=\"https:\/\/machinerysafety101.com\/2026\/03\/18\/fault-masking-e-stops-interlocks\/\" target=\"_blank\" rel=\"noopener\">An\u00e1lise da Conformidade na Consultoria de Vis\u00e3o da ISO 14119:2024 Anexo J<\/a>, cada contato pode ter um MTTFD t\u00edpico de 80 anos. No entanto, abrir e fechar uma prote\u00e7\u00e3o a jusante \u00edntegra em uma cadeia em s\u00e9rie passiva reinicia o rel\u00e9 de seguran\u00e7a e mascara um contato a montante soldado.<\/p>\n<p>Este efeito de mascaramento de falhas viola o requisito EN ISO 13849-1 Categoria 3 e Categoria 4 de que cada falha deve ser capturada em ou antes da pr\u00f3xima demanda de seguran\u00e7a. Quando quatro ou mais intertravamentos passivos s\u00e3o conectados em s\u00e9rie com aberturas de portas frequentes, a Cobertura de Diagn\u00f3stico (DCavg) cai abaixo de 60% (Baixa).Aquela gota cobre toda a cadeia de seguran\u00e7a em PL c.<\/p>\n<h3 id=\"h3-q3\">Os dispositivos OSSD podem ser encadeados em diferentes fabricantes?<\/h3>\n<p>Os dispositivos OSSD de diferentes fabricantes podem ser encadeados em s\u00e9rie quando o sensor downstream fornece entradas de seguran\u00e7a dedicadas compat\u00edveis com OSSD (SI1 e SI2).O seu filtro de entrada deve aceitar a largura de pulso de teste do sensor upstream (T1: 150 us a 1 ms) e o per\u00edodo (T2: 100 ms a 200 ms).Se as janelas de pulso n\u00e3o corresponderem, conecte cada sensor a um par de entrada de seguran\u00e7a separado ou a um n\u00f3 de barramento ativo.<\/p>\n<p>Para fazer a cascata de m\u00faltiplos sensores OSSD preservando a cobertura diagn\u00f3stica da categoria 4 \/PL e e transmitindo informa\u00e7\u00f5es diagn\u00f3sticas completas para a IHM, duas arquiteturas comprovadas em campo s\u00e3o<\/p>\n<ul>\n<li>N\u00f3s de diagn\u00f3stico ativos em cascata sobre um loop M12: conforme relatado por <a href=\"https:\/\/www.automationworld.com\/products\/control\/product\/13311932\/sick-inc-safety-controller-with-flexi-loop\" target=\"_blank\" rel=\"noopener\">Mundo da Automa\u00e7\u00e3o no SICK Flexi Loop<\/a>, n\u00f3s de loop M12 ativos conectam em cascata at\u00e9 32 sensores com 30 metros por segmento em PLe. Cada n\u00f3 monitora os pulsos escuros OSSD de seu sensor local de forma independente. Em seguida, envia informa\u00e7\u00f5es de diagn\u00f3stico em n\u00edvel de pino de volta para o controlador de seguran\u00e7a.<\/li>\n<li>Fia\u00e7\u00e3o ponto a ponto de seguran\u00e7a IO-Link sob IEC 61139-2: conforme relatado em <a href=\"https:\/\/www.pilz.com\/en-US\/products\/connectivity\/io-link-safety\" target=\"_blank\" rel=\"noopener\">Pilz IO-Link Documenta\u00e7\u00e3o de seguran\u00e7a<\/a>, a comunica\u00e7\u00e3o ponto-a-ponto segura alcan\u00e7a PL e (SIL 3) e permanece independente do fieldbus superior. Cada dispositivo OSSD conecta atrav\u00e9s de um cabo M12 n\u00e3o blindado a uma porta mestre, eliminando completamente o mascaramento de falha em s\u00e9rie.<\/li>\n<\/ul>\n<p>Ao fazer a cascata de sensores OSSD atrav\u00e9s de entradas em cascata SI1 e SI2, tenha em mente que o atraso de desligamento \u00e9 cumulativo. Inclua o tempo de resposta OSSD do sensor upstream ao calcular sua dist\u00e2ncia de seguran\u00e7a de acordo com o padr\u00e3o de seguran\u00e7a OSHA 29 CFR 1910.217.<\/p>\n<\/section>\n<section id=\"h2-8\">\n<h2>Limites de carga el\u00e9trica, capacit\u00e2ncia do cabo e c\u00e1lculos de comprimento m\u00e1ximo do fio<\/h2>\n<figure style=\"margin:28px 0; text-align:center;\"><img decoding=\"async\" src=\"https:\/\/industrialsafetysensor.com\/wp-content\/uploads\/2026\/11\/ossd-wiring-guide-h2_08.png\" class=\"wp-image-4521\" width=\"1200\" height=\"800\" loading=\"lazy\" style=\"max-width:100%; height:auto; border-radius:8px;\" alt=\"Ilustra os dois limites f\u00edsicos no comprimento do cabo OSSD: queda de tens\u00e3o de resist\u00eancia do loop e distor\u00e7\u00e3o de capacit\u00e2ncia de pulso RC.\" \/><\/figure>\n<p>O circuito de seguran\u00e7a OSSD da fam\u00edlia de sensores industriais pode ser de at\u00e9 100-300 metros. Dois limites f\u00edsicos governam este comprimento: queda de tens\u00e3o de resist\u00eancia do loop DC (mantendo a tens\u00e3o terminal igual ou superior a 21 V sob carga) e capacit\u00e2ncia do cabo RC linha-terra. Capacit\u00e2ncia excessiva, entre outras coisas, arredonda pulsos de teste escuros de microssegundos e causa falhas cruzadas curtas.<\/p>\n<p>De acordo com <a href=\"https:\/\/industrialmonitordirect.com\/blogs\/knowledgebase\/how-ossd-safety-outputs-work-electrical-operation-explained\" target=\"_blank\" rel=\"noopener\">especifica\u00e7\u00f5es industriais OSSD<\/a>, as sa\u00eddas OSSD exigem um m\u00ednimo de 21 V nos terminais do dispositivo sob carga. Os modelos industriais padr\u00e3o permitem at\u00e9 100-300 m de cabos. No entanto, abaixo <a href=\"https:\/\/www.osha.gov\/laws-regs\/regulations\/standardnumber\/1910\/1910.217\" target=\"_blank\" rel=\"noopener\">OSHA 29 CFR 1910.217(b)(8)(iii)<\/a>, os circuitos de comando CC n\u00e3o devem exceder uma classifica\u00e7\u00e3o nominal de 240 V d.c. Na pr\u00e1tica, o PELV de 24 V CC serve como tens\u00e3o de seguran\u00e7a padr\u00e3o global para dispositivos OSSD.<\/p>\n<p>Limita\u00e7\u00e3o &amp; Efeito de Capacit\u00e2ncia: Cabos multicondutores longos n\u00e3o blindados com alta capacit\u00e2ncia linha-terra arredondam os pulsos de teste OSSD de sub-milissegundos. Essa distor\u00e7\u00e3o impede que o comparador de realimenta\u00e7\u00e3o interno do sensor enxergue o estado de 0 V antes que a janela de pulso expire. Se a capacit\u00e2ncia parasita do cabo (C_cable) descarregar lentamente atrav\u00e9s da imped\u00e2ncia de entrada do rel\u00e9 de seguran\u00e7a (R_load), o OSSD1 permanece acima do limiar baixo durante uma janela de pulso de 150 \u03bcs. O sensor interpreta esse decaimento RC lento como um curto-circuito para +24 V CC e entra em bloqueio.<\/p>\n<div class=\"worked-example\">\n<p>C\u00e1lculo de engenharia trabalhado: funcionamento do cabo M12 de 30 metros (queda de tens\u00e3o e verifica\u00e7\u00e3o de distor\u00e7\u00e3o de pulso RC)<\/p>\n<p>Considere conectar um receptor de cortina de luz de seguran\u00e7a Tipo 4 a um segmento de cabo M12 de 30 metros (correspondendo ao <a href=\"https:\/\/www.automationworld.com\/products\/control\/product\/13311932\/sick-inc-safety-controller-with-flexi-loop\" target=\"_blank\" rel=\"noopener\">30 metros por segmento<\/a> benchmark).A corrida usa 22 AWG (0,34 mm\u00b2) cabo blindado para alimentar uma entrada de seguran\u00e7a PLC F-DI.<\/p>\n<ol>\n<li>Na Etapa 1, calcule a queda de tens\u00e3o do terminal contra a regra m\u00ednima de 21 V. Um condutor de cobre de 22 AWG tem uma resist\u00eancia de 0,053 ohms por metro. Sobre uma corrida de 30 metros (loop de ida e volta de 60 metros) transportando 0,25 A de corrente total, a queda de tens\u00e3o do loop \u00e9 igual a 60 m * 0,053 ohms\/m * 0,25 A = 0,80 V. Com uma alimenta\u00e7\u00e3o CC de 24 V, a tens\u00e3o do terminal do receptor \u00e9 de 24,0 V 0,80 V = 23,2 V, o que excede com seguran\u00e7a o <strong>21V<\/strong> limiar m\u00ednimo.<\/li>\n<li>Passo 2\n<p>Calcule a constante de tempo de descarga RC contra a largura de pulso OSSD T1. a 120 pF\/m de capacit\u00e2ncia n\u00facleo-escudo, um cabo de 30 metros adiciona 3,6 nF (3.600 pF) de capacit\u00e2ncia de linha emparelhada com uma imped\u00e2ncia de entrada de seguran\u00e7a de 3.000 ohm, a constante de tempo RC (tau = R * C) equivale a 3.000 ohms * 3,6 nF = 10,8 microssegundos.<\/li>\n<li>Na Etapa 3, compare a janela de descarga 3*tau contra a largura de pulso m\u00ednima de 150 us. A descarga total abaixo do limite l\u00f3gico de 0 V leva 3 * tau = 32,4 microssegundos O decaimento de 32,4 us \u00e9 inferior a um quarto da largura de pulso de teste escuro OSSD m\u00ednima de 150 us em <a href=\"https:\/\/webhelp.kollmorgen.com\/akd2g\/english\/content\/akd2g-s%20install\/e\/fsm\/AKD2S_install_20_06_OSSD.htm\" target=\"_blank\" rel=\"noopener\">Tabela de cronometragem OSSD de Kollmorgen<\/a>, portanto, o pulso atinge 0 V de forma limpa.<\/li>\n<\/ol>\n<\/div>\n<\/section>\n<section id=\"h2-9\">\n<h2>Solu\u00e7\u00e3o de problemas Lista de verifica\u00e7\u00e3o de especifica\u00e7\u00f5es de fia\u00e7\u00e3o e compras do OSSD<\/h2>\n<figure style=\"margin:28px 0; text-align:center;\"><img decoding=\"async\" src=\"https:\/\/industrialsafetysensor.com\/wp-content\/uploads\/2026\/11\/ossd-wiring-guide-h2_09.png\" class=\"wp-image-4522\" width=\"1200\" height=\"800\" loading=\"lazy\" style=\"max-width:100%; height:auto; border-radius:8px;\" alt=\"Combina verifica\u00e7\u00e3o de forma de onda do oscilosc\u00f3pio, verifica\u00e7\u00f5es de curto-circuito cruzado de cordset, testes de loop EDM e especifica\u00e7\u00f5es de transfer\u00eancia de aquisi\u00e7\u00e3o.\" \/><\/figure>\n<p>A solu\u00e7\u00e3o de problemas OSSD eficaz isola se um bloqueio de falha \u00e9 causado por desalinhamento do feixe \u00f3ptico, uma liga\u00e7\u00e3o comum de 0 V ausente, um pulso de teste colidindo com um PLC de seguran\u00e7a ou um loop de contator EDM aberto A medi\u00e7\u00e3o de OSSD1 e OSSD2 com um mult\u00edmetro digital padr\u00e3o n\u00e3o pode encontrar colis\u00f5es de pulso, porque a m\u00e9dia do medidor \u00e9 inferior a um milissegundo.<\/p>\n<p>Como mostrado em <a href=\"https:\/\/forum.digikey.com\/t\/ossd-safety-signals-what-the-waveform-tells-a-safety-relay\/57545\" target=\"_blank\" rel=\"noopener\">Guia diagn\u00f3stico do oscilosc\u00f3pio de dois canais da DigiKey<\/a>, a cada 200 ms, um dos dois canais do oscilosc\u00f3pio de sinal mergulha temporariamente baixo. Como mostrado no guia de diagn\u00f3stico do oscilosc\u00f3pio de dois canais da DigiKey, cada sinal mergulha periodicamente baixo uma vez a cada 200 ms Conectando o Canal 1 ao OSSD1 e o Canal 2 ao OSSD2 exp\u00f5e imediatamente pulsos de teste ausentes ou acoplamento entre canais. Para atualiza\u00e7\u00f5es com fio para troncos de diagn\u00f3stico inteligentes, <a href=\"https:\/\/www.pilz.com\/en-US\/products\/connectivity\/io-link-safety\" target=\"_blank\" rel=\"noopener\">Seguran\u00e7a Pilz IO-Link<\/a> garante que comunica\u00e7\u00f5es seguras, ponto a ponto, atinjam o n\u00edvel PL e (SIL 3), ao mesmo tempo que transmitem c\u00f3digos de falha ao vivo para o PLC.<\/p>\n<p>Por fim, mantenha registros de valida\u00e7\u00e3o anuais documentados para cada linha de imprensa. Conforme declarado em <a href=\"https:\/\/www.osha.gov\/laws-regs\/regulations\/standardnumber\/1910\/1910.217\" target=\"_blank\" rel=\"noopener\">OSHA 29 CFR 1910.217(h)(10)(ii)<\/a>, qualquer sistema de seguran\u00e7a da prensa PSDI deve ser recertificado e revalidado a cada 12 meses. Se uma prensa passar 12 meses sem revalida\u00e7\u00e3o, ela deve ser removida do servi\u00e7o PSDI imediatamente.<\/p>\n<h3 id=\"h3-q4\">Que condi\u00e7\u00f5es devem ser cumpridas para que um OSSD mantenha um estado ON seguro?<\/h3>\n<p>Quatro condi\u00e7\u00f5es el\u00e9tricas e \u00f3pticas devem ser satisfeitas para que um par OSSD esteja no estado seguro de 24 V ligado. A tens\u00e3o de alimenta\u00e7\u00e3o nos terminais deve ser de 21 V CC ou mais, e o campo de detec\u00e7\u00e3o de prote\u00e7\u00e3o deve estar desobstru\u00eddo. Al\u00e9m disso, os pulsos de teste escuros de 0 V em OSSD1 e OSSD2 devem ocorrer sem falhas cruzadas, e o loop de rearme EDM deve fechar.<\/p>\n<div class=\"table-responsive\">\n<div class=\"ecc-table-scroll\" style=\"overflow-x:auto;\">\n<table>\n<caption>Tabela 6: Matriz de solu\u00e7\u00e3o de problemas de campo para falhas de sa\u00edda de seguran\u00e7a OSSD<\/caption>\n<thead>\n<tr>\n<th>Sintoma Observado<\/th>\n<th>Raiz Causa El\u00e9trica<\/th>\n<th>M\u00e9todo de Verifica\u00e7\u00e3o Diagn\u00f3stica<\/th>\n<th>A\u00e7\u00e3o Corretiva de Fia\u00e7\u00e3o<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>OSSD1 &amp; OSSD2 Preso em 0 V (feixe claro, falha LED piscando)<\/strong><\/td>\n<td>fio OSSD em curto-circuito para +24 V DC ou em curto-circuito cruzado entre o Pin 2 e o Pin 4<\/td>\n<td>Desconecte S12\/S22 no rel\u00e9 e verifique a continuidade entre o pino 2, o pino 4 e o pino 1<\/td>\n<td>Substitua o conjunto de cabos M12 danificado e o ciclo de energia CC de 24 V para limpar a trava de falha interna<\/td>\n<\/tr>\n<tr>\n<td><strong>Falhas de seguran\u00e7a do PLC F-DI a cada poucos segundos quando limpo<\/strong><\/td>\n<td>pulso de teste de rel\u00f3gio interno PLC (T0\/T1) colidindo com o pulso escuro OSSD do sensor<\/td>\n<td>Inspecione a configura\u00e7\u00e3o do canal F-DI no TIA Portal\/Est\u00fadio 5000\/GinwSAFE<\/td>\n<td>Desative pulsos internos de teste PLC em ambos os canais; defina o tempo de discrep\u00e2ncia para 50-100 ms<\/td>\n<\/tr>\n<tr>\n<td><strong>Viagens de rel\u00e9 de seguran\u00e7a em funcionamento de cabo longo (&gt;50 m)<\/strong><\/td>\n<td>Capacit\u00e2ncia do cabo arredondando 150 us desligando pulso de teste de 1 ms ou queda de tens\u00e3o abaixo de 21V<\/td>\n<td>Escopo OSSD1\/OSSD2 no receptor vs. rel\u00e9; medir a tens\u00e3o CC sob carga<\/td>\n<td>Mude para o cabo de baixa capacit\u00e2ncia, aumente o medidor de fio ou encurte o tronco abaixo de 30 m<\/td>\n<\/tr>\n<tr>\n<td><strong>Sa\u00eddas verdes no sensor, rel\u00e9 de seguran\u00e7a K1\/K2 n\u00e3o ser\u00e1 acionado<\/strong><\/td>\n<td>Abra o la\u00e7o de EDM (contato auxiliar de K1\/K2 NC preso aberto) ou a refer\u00eancia flutuante de 0V<\/td>\n<td>Me\u00e7a a continuidade em K1 (21-22) e K2 (21-22) em s\u00e9rie com S33-S34<\/td>\n<td>Substitua o contator guiado por for\u00e7a defeituoso ou o sensor de liga\u00e7\u00e3o 0 V (Pin 3) para retransmitir A2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<section class=\"ecc-rfq-checklist\" data-component=\"rfq-checklist\">\n<h3>Lista de verifica\u00e7\u00e3o de especifica\u00e7\u00f5es de aquisi\u00e7\u00e3o de sensores de seguran\u00e7a e chicotes el\u00e9tricos OSSD<\/h3>\n<p>Antes de enviar uma Solicita\u00e7\u00e3o de Cota\u00e7\u00e3o (RFQ) ou finalizar seu esquema de fia\u00e7\u00e3o com <a href=\"https:\/\/industrialsafetysensor.com\/pt\/about-us\/\">CCH Shanghai Tecnologia e Intelig\u00eancia Co.<\/a>, assegure-se de que os seguintes sete itens de especifica\u00e7\u00e3o sejam revisados:<\/p>\n<ul>\n<li>Especifique EN IEC 61496-1 Tipo 4 (EN ISO 13849-1 Categoria 4 \/ PL e, SIL 3) ou Tipo 2 (PL c \/ SIL 1) para corresponder \u00e0 avalia\u00e7\u00e3o de risco da sua m\u00e1quina.<\/li>\n<li>Selecione sa\u00eddas OSSD de fonte PNP de 24 VDC de canal duplo e verifique se a largura do pulso (T1: 150 us a 1 ms) e o per\u00edodo (T2: 100 ms a 200 ms) correspondem ao seu controlador.<\/li>\n<li>Escolha os cordsets M12 de 5 pinos quando um rel\u00e9 de seguran\u00e7a externo gerencia EDM e redefinir, ou selecione os cordsets M12 de 8 pinos\/12 pinos ao usar EDM integrado e reiniciar o intertravamento.<\/li>\n<li>Defina o comprimento exato da passagem do cabo (padr\u00e3o 30 m \/m\u00e1x. 100 a 300 m) para garantir que a tens\u00e3o dos terminais esteja igual ou superior a 21 V sob carga total.<\/li>\n<li>Estipule que OSSD1 e OSSD2 pousem em um rel\u00e9 de seguran\u00e7a dedicado (S12 \/S22), uma placa Safety PLC F-DI ou uma entrada STO de acionamento seguro.<\/li>\n<li>Fa\u00e7a parceria com o sensor com contatores K1\/K2 guiados por for\u00e7a (IEC 60947-4-1) e verifique o tempo de parada da prensa para verificar a conformidade com a dist\u00e2ncia de seguran\u00e7a OSHA 29 CFR 1910.217.<\/li>\n<li>Precisa de desenhos de pinagem, arquivos CAD STEP ou revis\u00e3o de engenharia de aplicativos? Entre em contato com nossa equipe atrav\u00e9s do <a href=\"https:\/\/industrialsafetysensor.com\/pt\/contact\/\">p\u00e1gina de contato de engenharia<\/a> (pre\u00e7os de cordset personalizados e prazos de entrega s\u00e3o fornecidos mediante solicita\u00e7\u00e3o).<\/li>\n<\/ul>\n<\/section>\n<\/section>\n<section id=\"faq\" class=\"ecc-faq-section\">\n<h2>Perguntas frequentes<\/h2>\n<details>\n<summary>\n<h3>O que significa OSSD em sensores de seguran\u00e7a?<\/h3>\n<\/summary>\n<p>OSSD significa Dispositivo de Comuta\u00e7\u00e3o de Sinal de Sa\u00edda sob a norma EN IEC 61496-1 Cl\u00e1usula 4.2.4. Trata-se de uma sa\u00edda de comuta\u00e7\u00e3o de estado s\u00f3lido de canal duplo inclu\u00edda em uma cortina de luz de seguran\u00e7a, um scanner a laser ou uma chave de seguran\u00e7a. Ambos os canais fornecem 24 V CC durante a opera\u00e7\u00e3o normal e caem para 0 V CC em milissegundos sempre que o campo de prote\u00e7\u00e3o \u00e9 interrompido.<\/p>\n<\/details>\n<details>\n<summary>\n<h3>Por que as sa\u00eddas OSSD usam dois canais (OSSD1 e OSSD2)?<\/h3>\n<\/summary>\n<p>As sa\u00eddas OSSD usam dois canais independentes (OSSD1 e OSSD2) para satisfazer as regras de redund\u00e2ncia de canal duplo EN ISO 13849-1 Categoria 3 e Categoria 4 (PL d e PL e). Cada canal \u00e9 acionado por seu pr\u00f3prio transistor e monitorado por um comparador interno. Se um transistor solda fechado ou um fio sofre uma falha cruzada, o segundo canal ainda desenergiza o rel\u00e9 de seguran\u00e7a e p\u00e1ra o perigo da m\u00e1quina imediatamente.<\/p>\n<\/details>\n<details>\n<summary>\n<h3>Posso conectar uma sa\u00edda OSSD diretamente a uma entrada digital PLC padr\u00e3o?<\/h3>\n<\/summary>\n<p>Nunca \u00e9 permitido conectar a sa\u00edda OSSD apenas a uma entrada digital PLC padr\u00e3o e sem seguran\u00e7a para prote\u00e7\u00e3o de pessoal. Um controlador l\u00f3gico program\u00e1vel padr\u00e3o usa um processador de canal \u00fanico e n\u00e3o possui detec\u00e7\u00e3o de falha cruzada certificada, temporizadores de discrep\u00e2ncia de entrada ou rel\u00e9s de sa\u00edda guiados por for\u00e7a. Voc\u00ea s\u00f3 pode conectar um status auxiliar a um PLC padr\u00e3o para exibi\u00e7\u00e3o HMI depois que OSSD1 e OSSD2 terminarem em um rel\u00e9 de seguran\u00e7a certificado ou m\u00f3dulo F-DI \u00e0 prova de falhas.<\/p>\n<\/details>\n<details>\n<summary>\n<h3>Como fa\u00e7o para impedir que um PLC de seguran\u00e7a falhe quando conectado a uma cortina de luz OSSD?<\/h3>\n<\/summary>\n<p>Desative as sa\u00eddas de pulso de teste de clock interno do Safety PLC nos dois canais F-DI conectados ao OSSD1 e OSSD2 Em seguida, defina os temporizadores de discrep\u00e2ncia de canal entre 50 ms e 100 ms.<\/p>\n<\/details>\n<details>\n<summary>\n<h3>Qual \u00e9 a diferen\u00e7a entre a fia\u00e7\u00e3o OSSD M12 de 5 e 8 pinos?<\/h3>\n<\/summary>\n<p>Um cabo receptor M12 de 5 pinos carrega +24 V (Pin 1), OSSD1 (Pin 2), 0 V (Pin 3), OSSD2 (Pin 4) e Functional Earth (Pin 5). Ele usa um rel\u00e9 de seguran\u00e7a externo para EDM e reset. Um conector M12 de 8 pinos fornece fios para feedback de contator EDM integrado e intertravamento de reinicializa\u00e7\u00e3o.<\/p>\n<\/details>\n<details>\n<summary>\n<h3>Por que as sa\u00eddas OSSD s\u00e3o quase sempre PNP em vez de NPN?<\/h3>\n<\/summary>\n<p>Os padr\u00f5es de seguran\u00e7a de m\u00e1quinas industriais exigem o uso de sa\u00eddas OSSD de fornecimento PNP porque os transistores PNP comutam o trilho positivo de 24 V. Em um circuito de controle PELV de 0 V aterrado, de acordo com IEC 60204-1 e OSHA 29 CFR 1910.217, um fio comprimido tocando a\u00e7o de m\u00e1quina aterrado em uma linha PNP cai para 0 V e imediatamente aciona um desligamento seguro. Em um circuito de afundamento NPN, a mesma falha de aterramento completa o caminho de 0 V e mant\u00e9m a m\u00e1quina em um estado ON ativo.<\/p>\n<\/details>\n<\/section>\n<section id=\"references\" class=\"ecc-references-section\">\n<h2>Refer\u00eancias e fontes<\/h2>\n<ol>\n<li>CENELEC \/ IEC TC 44 \u2013 <a href=\"https:\/\/standards.iteh.ai\/catalog\/standards\/clc\/b77ec184-b687-47c0-b4fd-874dc25d41b8\/en-iec-61496-1-2020\" target=\"_blank\" rel=\"noopener\">EN IEC 61496-1:2020 Seguran\u00e7a de m\u00e1quinas \u2013 Equipamento de prote\u00e7\u00e3o eletrossens\u00edvel \u2013 Parte 1: Requisitos gerais e ensaios (Cl\u00e1usulas 4.2.4, 5.2.8 &amp; Anexo A.2)<\/a><\/li>\n<li>Administra\u00e7\u00e3o de Seguran\u00e7a e Sa\u00fade Ocupacional dos EUA (OSHA) (OSHA) <a href=\"https:\/\/www.osha.gov\/laws-regs\/regulations\/standardnumber\/1910\/1910.217\" target=\"_blank\" rel=\"noopener\">29 Prensas Mec\u00e2nicas de Pot\u00eancia CFR 1910.217: Circuitos de Controle, Monitores de Freio e Dist\u00e2ncia de Seguran\u00e7a PSDI<\/a><\/li>\n<li>USA eTools (OSHA eTools) <a href=\"https:\/\/www.osha.gov\/etools\/machine-guarding\/presses\/presence-sensing-devices\" target=\"_blank\" rel=\"noopener\">Guarda-m\u00e1quinas: dispositivos de detec\u00e7\u00e3o de presen\u00e7a e requisitos de silenciamento<\/a><\/li>\n<li>Instituto Europeu de Patentes (SICK AG) (SICK AG) <a href=\"https:\/\/patents.google.com\/patent\/EP3358592B1\/en\" target=\"_blank\" rel=\"noopener\">Dispositivo de comuta\u00e7\u00e3o de sinal de sa\u00edda (OSSD) EP3358592B1 com detec\u00e7\u00e3o cruzada de m\u00faltiplas tens\u00f5es<\/a><\/li>\n<li>F\u00f3rum de Engenharia DigiKey. <a href=\"https:\/\/forum.digikey.com\/t\/ossd-safety-signals-what-the-waveform-tells-a-safety-relay\/57545\" target=\"_blank\" rel=\"noopener\">Sinais de seguran\u00e7a OSSD: o que a forma de onda indica a um rel\u00e9 de seguran\u00e7a (capturas de oscilosc\u00f3pio)<\/a><\/li>\n<li>Documenta\u00e7\u00e3o T\u00e9cnica Kollm (Kollm Technical Documentation) <a href=\"https:\/\/webhelp.kollmorgen.com\/akd2g\/english\/content\/akd2g-s%20install\/e\/fsm\/AKD2S_install_20_06_OSSD.htm\" target=\"_blank\" rel=\"noopener\">Instala\u00e7\u00e3o de movimento seguro AKD2 G: Especifica\u00e7\u00f5es de temporiza\u00e7\u00e3o de pulso de teste escuro OSSD (T1\/T2)<\/a><\/li>\n<li>Beckhoff Automation EUA. <a href=\"https:\/\/www.blog.beckhoffus.com\/post\/test-pulses-vs-ossd\" target=\"_blank\" rel=\"noopener\">TwinSAFE EL1918 e EL1904: Pulsos de teste vs. Configura\u00e7\u00e3o OSSD<\/a><\/li>\n<li>Compliance inSight Consulting (Machinery Safety 101) \u2014<br \/>\n<a href=\"https:\/\/machinerysafety101.com\/2026\/03\/18\/fault-masking-e-stops-interlocks\/\" target=\"_blank\" rel=\"noopener\">Mascaramento de falhas em intertravamentos conectados em s\u00e9rie sob ISO 14119:2024 Anexo J e ISO\/TR 24119<\/a><\/li>\n<li>Automa\u00e7\u00e3o Mundial (Automation World)<br \/>\n<a href=\"https:\/\/www.automationworld.com\/products\/control\/product\/13311932\/sick-inc-safety-controller-with-flexi-loop\" target=\"_blank\" rel=\"noopener\">controlador de seguran\u00e7a SICK com Flexi Loop: Cascading 32 sensores OSSD em PL e<\/a><\/li>\n<li>Pilz Automa\u00e7\u00e3o ist.<br \/>\n<a href=\"https:\/\/www.pilz.com\/en-US\/products\/connectivity\/io-link-safety\" target=\"_blank\" rel=\"noopener\">Comunica\u00e7\u00e3o ponto a ponto de seguran\u00e7a IO-Link at\u00e9 PL e \/ SIL 3 (IEC 61139-2)<\/a><\/li>\n<li>Monitor Industrial Base de Conhecimento Direta.<br \/>\n<a href=\"https:\/\/industrialmonitordirect.com\/blogs\/knowledgebase\/how-ossd-safety-outputs-work-electrical-operation-explained\" target=\"_blank\" rel=\"noopener\">Como funcionam as sa\u00eddas de seguran\u00e7a OSSD: opera\u00e7\u00e3o el\u00e9trica, filtros de entrada e queda de cabo<\/a><\/li>\n<li>Guia de aplica\u00e7\u00e3o de fia\u00e7\u00e3o Dadi\/SICK (SICK Wiring Application Guide)<br \/>\n<a href=\"https:\/\/m.dadisick.com\/blog\/How-to-Wire-a-Safety-Light-Curtain-NPN-PNP-Wiring-Diagrams-Common-Issues_b13976\" target=\"_blank\" rel=\"noopener\">Como conectar uma cortina de luz de seguran\u00e7a: diagramas de fia\u00e7\u00e3o NPN vs. PNP e pinouts de conector<\/a><\/li>\n<\/ol>\n<\/section>\n<\/article>","protected":false},"excerpt":{"rendered":"<p>By CYH \u00b7 Reviewed by the CCH Shanghai Technology and Intelligence Co., Ltd. safety engineering team A OSSD Wiring Guide illustrates how to wire a dual channel safety output (OSSD1 and OSSD2) to a safety relay or safety PLC across 1 to 300 m runs. Both channels source 24 V during normal operation and go [&hellip;]<\/p>\n","protected":false},"author":10,"featured_media":4513,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-4523","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-qjkh-blogs"],"_links":{"self":[{"href":"https:\/\/industrialsafetysensor.com\/pt\/wp-json\/wp\/v2\/posts\/4523","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/industrialsafetysensor.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/industrialsafetysensor.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/industrialsafetysensor.com\/pt\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/industrialsafetysensor.com\/pt\/wp-json\/wp\/v2\/comments?post=4523"}],"version-history":[{"count":0,"href":"https:\/\/industrialsafetysensor.com\/pt\/wp-json\/wp\/v2\/posts\/4523\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/industrialsafetysensor.com\/pt\/wp-json\/wp\/v2\/media\/4513"}],"wp:attachment":[{"href":"https:\/\/industrialsafetysensor.com\/pt\/wp-json\/wp\/v2\/media?parent=4523"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/industrialsafetysensor.com\/pt\/wp-json\/wp\/v2\/categories?post=4523"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/industrialsafetysensor.com\/pt\/wp-json\/wp\/v2\/tags?post=4523"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}