{"id":1474,"date":"2026-04-11T09:59:28","date_gmt":"2026-04-11T09:59:28","guid":{"rendered":"https:\/\/industrialsafetysensor.com\/?page_id=1474"},"modified":"2026-10-31T13:41:18","modified_gmt":"2026-10-31T13:41:18","slug":"safety-relay-modules","status":"publish","type":"page","link":"https:\/\/industrialsafetysensor.com\/de\/safety-relay-modules\/","title":{"rendered":"Sicherheitsrelaismodule"},"content":{"rendered":"\n<!-- Replace all eight old SRB content blocks with this complete block. -->\n<style>\n.cch-srb-page{--ink:#102f3f;--muted:#526775;--line:#dce5ea;--blue:#0879b5;color:var(--ink);font-family:inherit;font-size:16px;line-height:1.7;overflow-wrap:anywhere}\n.cch-srb-page,.cch-srb-page *{box-sizing:border-box}\n.cch-srb-page .srb-wrap{width:min(1180px,100%);margin-inline:auto}\n.cch-srb-page .srb-section{padding:64px 28px;scroll-margin-top:120px}\n.cch-srb-page [id]{scroll-margin-top:120px}\n.cch-srb-page .srb-light{background:#f5f8fa}\n.cch-srb-page h1,.cch-srb-page h2,.cch-srb-page h3{font-family:inherit;color:var(--ink);letter-spacing:-.025em}\n.cch-srb-page h1{font-size:clamp(34px,4.7vw,58px);line-height:1.12;margin:0;max-width:950px}\n.cch-srb-page h2{font-size:clamp(27px,3vw,36px);line-height:1.2;margin:0 0 18px}\n.cch-srb-page h3{font-size:20px;line-height:1.35;margin:0 0 10px}\n.cch-srb-page p{margin:0 0 16px}\n.cch-srb-page p:last-child{margin-bottom:0}\n.cch-srb-page a{color:var(--blue);text-underline-offset:4px}\n.cch-srb-page a:focus-visible,.cch-srb-page summary:focus-visible,.cch-srb-page .srb-table-wrap:focus-visible{outline:3px solid #168cc7;outline-offset:5px}\n.cch-srb-page .srb-kicker{font-size:12px;font-weight:700;letter-spacing:.12em;text-transform:uppercase;margin-bottom:14px;color:var(--blue)}\n.cch-srb-page .srb-hero{background:var(--ink);color:#cbdde6;padding-top:72px;padding-bottom:56px}\n.cch-srb-page .srb-hero h1{color:#fff}\n.cch-srb-page .srb-hero .srb-kicker{color:#75d1f7}\n.cch-srb-page .srb-lead{max-width:850px;font-size:18px;line-height:1.75;margin:22px 0 0}\n.cch-srb-page .srb-actions{display:flex;flex-wrap:wrap;gap:12px;margin-top:26px}\n.cch-srb-page .srb-btn{display:inline-flex;align-items:center;justify-content:center;min-height:48px;padding:13px 22px;background:#0879b5;color:#fff!important;border:1px solid transparent;border-radius:4px;font-size:15px;font-weight:700;line-height:1.4;text-decoration:none;text-align:center}\n.cch-srb-page .srb-btn:hover{background:#066797}\n.cch-srb-page .srb-outline{background:transparent;border-color:#7b96a5}\n.cch-srb-page .srb-outline:hover{background:#234757}\n.cch-srb-page .srb-stats{display:grid;grid-template-columns:repeat(4,minmax(0,1fr));gap:0;margin:34px 0 0;border-top:1px solid #426171;padding-top:22px}\n.cch-srb-page .srb-stats div{padding:0 20px;border-right:1px solid #426171}\n.cch-srb-page .srb-stats div:first-child{padding-left:0}\n.cch-srb-page .srb-stats div:last-child{border:0}\n.cch-srb-page .srb-stats dt{color:#fff;font-size:20px;font-weight:700;line-height:1.4}\n.cch-srb-page .srb-stats dd{font-size:13px;margin:5px 0 0}\n.cch-srb-page .srb-grid{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:18px;margin-top:26px}\n.cch-srb-page .srb-two{grid-template-columns:repeat(2,minmax(0,1fr))}\n.cch-srb-page .srb-card{padding:24px;border:1px solid var(--line);border-radius:8px;background:#fff}\n.cch-srb-page .srb-card p{color:var(--muted);font-size:15px}\n.cch-srb-page .srb-subsection{margin-top:36px}\n.cch-srb-page .srb-note{padding:16px 20px;border-left:3px solid #0879b5;background:#eaf3f8;margin-top:22px;font-size:14px;color:#354f5f}\n.cch-srb-page .srb-table-wrap{overflow-x:auto;margin-top:18px;border:1px solid var(--line);border-radius:6px}\n.cch-srb-page table{width:100%;border-collapse:collapse;margin:0;font-size:15px;text-align:left}\n.cch-srb-page caption{text-align:left;padding:14px 18px;font-weight:700;background:#edf3f6;color:var(--ink)}\n.cch-srb-page th,.cch-srb-page td{padding:13px 18px;border:0;border-bottom:1px solid var(--line);vertical-align:top;line-height:1.6}\n.cch-srb-page thead th{background:#f5f8fa;font-weight:700}\n.cch-srb-page tbody th{font-weight:600;width:34%}\n.cch-srb-page tr:last-child th,.cch-srb-page tr:last-child td{border-bottom:0}\n.cch-srb-page .srb-small{font-size:14px;color:var(--muted)}\n.cch-srb-page details{border-bottom:1px solid var(--line);padding:16px 0}\n.cch-srb-page summary{cursor:pointer;font-weight:700;padding-right:12px;line-height:1.5}\n.cch-srb-page details p{margin-top:14px;color:var(--muted)}\n.cch-srb-page .srb-links{display:flex;flex-wrap:wrap;gap:12px 24px;padding:0;list-style:none;margin:20px 0 0}\n.cch-srb-page .srb-cta{margin-top:32px;padding:28px;background:#eaf3f8;border-radius:8px}\n@media(max-width:850px){.cch-srb-page .srb-grid{grid-template-columns:1fr 1fr}.cch-srb-page .srb-section{padding:46px 20px}.cch-srb-page .srb-hero{padding-top:54px}.cch-srb-page .srb-stats{grid-template-columns:1fr 1fr;gap:20px}.cch-srb-page .srb-stats div{padding:0;border:0}}\n@media(max-width:560px){.cch-srb-page .srb-grid{grid-template-columns:1fr}.cch-srb-page .srb-card{padding:20px}.cch-srb-page .srb-lead{font-size:17px}.cch-srb-page .srb-actions{flex-direction:column}.cch-srb-page th,.cch-srb-page td{padding:12px;font-size:14px}.cch-srb-page .srb-cta{padding:22px}.cch-srb-page .srb-links{flex-direction:column}}\n<\/style>\n\n<div class=\"cch-srb-page\">\n<!-- 01: Overview -->\n<section id=\"overview\" class=\"srb-section srb-hero\" aria-labelledby=\"srb-title\">\n <div class=\"srb-wrap\">\n  <p class=\"srb-kicker\">CCH \u00b7 Machine Safety Control<\/p>\n  <h1 id=\"srb-title\">SRB-2A1B Safety Relay Module<\/h1>\n  <p class=\"srb-lead\">Monitor compatible dual-channel safety-device signals and interface with downstream machine safety circuits. Supports selectable NPN \/ PNP inputs, manual or automatic reset, and dedicated muting control inputs.<\/p>\n  <div class=\"srb-actions\">\n   <a class=\"srb-btn\" href=\"\/contact-us\/\">Discuss Your Application<\/a>\n   <a class=\"srb-btn srb-outline\" href=\"#safety-performance-specifications\">View Specifications<\/a>\n  <\/div>\n  <dl class=\"srb-stats\">\n   <div><dt>NPN \/ PNP<\/dt><dd>Selectable dual-channel input<\/dd><\/div>\n   <div><dt>2 NO + 1 NC<\/dt><dd>Relay contacts<\/dd><\/div>\n   <div><dt>&lt;10 ms<\/dt><dd>Module response time<\/dd><\/div>\n   <div><dt>24 VDC \u00b110%<\/dt><dd>Operating supply<\/dd><\/div>\n  <\/dl>\n <\/div>\n<\/section>\n\n<!-- 02: Functions and compatible devices -->\n<section id=\"core-functions\" class=\"srb-section\" aria-labelledby=\"srb-functions-title\">\n <div class=\"srb-wrap\">\n  <p class=\"srb-kicker\">Core Functions<\/p>\n  <h2 id=\"srb-functions-title\">From Protective Signals to Relay Outputs<\/h2>\n  <div class=\"srb-grid\">\n   <article class=\"srb-card\"><h3>Dual-Channel Monitoring<\/h3><p>Monitors compatible safety-device signals, with selectable dual NPN or dual PNP input modes and channel-consistency monitoring.<\/p><\/article>\n   <article class=\"srb-card\"><h3>Reset &amp; Muting Control<\/h3><p>Manual or automatic reset configuration, with dedicated MUT_H \/ MUT_L inputs for the documented muting \/ shielding function.<\/p><\/article>\n   <article class=\"srb-card\"><h3>Status &amp; Installation<\/h3><p>CH1, CH2, ERROR and POWER indicators, reverse-polarity protection, detachable terminals and 35 mm DIN-rail mounting.<\/p><\/article>\n  <\/div>\n  <div id=\"safety-device-integration\" class=\"srb-subsection\">\n   <h3>Safety Device Integration<\/h3>\n   <div class=\"srb-grid srb-two\">\n    <article class=\"srb-card\"><h3>ENT Safety Light Curtains<\/h3><p>Dual-channel monitoring for the documented ENT integration. Match the SRB input mode to the selected light curtain&#8217;s output configuration.<\/p><a href=\"\/safety-light-curtains\/type-4-safety-light-curtain\/\">Explore ENT Light Curtains \u2192<\/a><\/article>\n    <article class=\"srb-card\"><h3>SH Safety Laser Scanners<\/h3><p>Monitoring of compatible SH safety signals where the electrical interface and safety architecture are suitable. Confirm the exact scanner output before integration.<\/p><a href=\"\/safety-laser-scanners\/\">Explore SH Safety Scanners \u2192<\/a><\/article>\n   <\/div>\n  <\/div>\n <\/div>\n<\/section>\n\n<!-- 03: Control and wiring -->\n<section class=\"srb-section srb-light\" aria-labelledby=\"srb-control-title\">\n <div class=\"srb-wrap\">\n  <p class=\"srb-kicker\">Control &amp; Wiring Reference<\/p>\n  <h2 id=\"srb-control-title\">Reset, Muting and Terminal Connections<\/h2>\n  <div id=\"reset-restart-logic\" class=\"srb-grid srb-two\">\n   <article class=\"srb-card\"><h3>Manual Reset<\/h3><p>Requires the defined reset action after the protective input condition is restored. The documented ENT arrangement uses an external reset switch in the SR \/ SRC path.<\/p><\/article>\n   <article class=\"srb-card\"><h3>Automatic Reset<\/h3><p>Allows the relay to recover when the required input conditions are restored. The documented automatic-reset arrangement directly connects SR and SRC.<\/p><\/article>\n  <\/div>\n  <p class=\"srb-note\"><strong>Reset is not machine restart.<\/strong> Select the reset mode and restart-prevention measures for the actual machine safety design. Restoring a protective field does not by itself establish permission for hazardous motion.<\/p>\n  <div id=\"muting-shielding-control\" class=\"srb-subsection\">\n   <h3>Muting \/ Shielding Control<\/h3>\n   <p>MUT_H and MUT_L are SRB control inputs. In the documented CCH arrangement, an ENT safety light curtain works with two external photoelectric sensors, two ordinary relays and the SRB-2A1B. Muting is not built into the ENT light curtain.<\/p>\n   <p class=\"srb-small\">The documented SRB muting state uses MUT_H at 24 V and MUT_L at 0 V; in this state, the connected light curtain signal does not affect the relay module. This state alone is not a complete muting design. External sensing, timing, wiring and machine response must be defined for the application.<\/p>\n   <a href=\"\/safety-light-curtains\/muting\/\">View the Safety Light Curtain Muting Guide \u2192<\/a>\n  <\/div>\n  <div id=\"wiring-terminal-reference\" class=\"srb-subsection\">\n   <h3>Terminal Reference<\/h3>\n   <div class=\"srb-table-wrap\" tabindex=\"0\" role=\"region\" aria-label=\"SRB terminal reference\">\n    <table>\n     <caption>Principal SRB-2A1B terminals<\/caption>\n     <thead><tr><th scope=\"col\">Terminal<\/th><th scope=\"col\">Documented Function<\/th><\/tr><\/thead>\n     <tbody>\n      <tr><th scope=\"row\">S12 \/ S22<\/th><td>ENT OSSD1 \u2192 S12; ENT OSSD2 \u2192 S22. Match the NPN \/ PNP selector to the actual ENT output configuration.<\/td><\/tr>\n      <tr><th scope=\"row\">SR \/ SRC<\/th><td>Reset control: external reset switch for manual reset; direct connection for automatic reset.<\/td><\/tr>\n      <tr><th scope=\"row\">MUT_H \/ MUT_L<\/th><td>Dedicated muting \/ shielding control inputs.<\/td><\/tr>\n      <tr><th scope=\"row\">13\u201314 \/ 23\u201324<\/th><td>Two normally open passive relay contact pairs.<\/td><\/tr>\n      <tr><th scope=\"row\">41\u201342<\/th><td>Normally closed auxiliary contact pair.<\/td><\/tr>\n     <\/tbody>\n    <\/table>\n   <\/div>\n   <p class=\"srb-note\"><strong>Wiring scope:<\/strong> The input example above is specific to documented ENT integration; do not reuse it as an unverified SH wiring diagram. These references are not a complete machine electrical drawing. Follow current device instructions, disconnect power before wiring, and validate the complete safety function before commissioning.<\/p>\n  <\/div>\n <\/div>\n<\/section>\n\n<!-- 04: Specifications -->\n<section id=\"safety-performance-specifications\" class=\"srb-section\" aria-labelledby=\"srb-spec-title\">\n <div class=\"srb-wrap\">\n  <p class=\"srb-kicker\">Technical Data<\/p>\n  <h2 id=\"srb-spec-title\">SRB-2A1B Specifications<\/h2>\n  <p class=\"srb-small\">Product values and ratings stated in CCH SRB-2A1B documentation.<\/p>\n  <div class=\"srb-table-wrap\" tabindex=\"0\" role=\"region\" aria-label=\"SRB technical specifications\">\n   <table>\n    <caption>Electrical, environmental and mechanical data<\/caption>\n    <thead><tr><th scope=\"col\">Parameter<\/th><th scope=\"col\">SRB-2A1B<\/th><\/tr><\/thead>\n    <tbody>\n     <tr><th scope=\"row\">Stated safety ratings<\/th><td>Cat. 4 \u00b7 PL e \u00b7 SIL 3<\/td><\/tr>\n     <tr><th scope=\"row\">Operating voltage \/ power<\/th><td>24 VDC \u00b110% \/ &lt;3 W<\/td><\/tr>\n     <tr><th scope=\"row\">Safety input<\/th><td>Dual NPN or dual PNP, selectable<\/td><\/tr>\n     <tr><th scope=\"row\">Relay output<\/th><td>2 NO + 1 NC passive contacts; NC contact is auxiliary<\/td><\/tr>\n     <tr><th scope=\"row\">Contact capacity<\/th><td>AC15: 5 A \/ 250 V<br>DC13: 6 A \/ 24 V<\/td><\/tr>\n     <tr><th scope=\"row\">Electrical life<\/th><td>\u22651,000,000 operations; dependent on switching conditions and load<\/td><\/tr>\n     <tr><th scope=\"row\">Response time<\/th><td>&lt;10 ms<\/td><\/tr>\n     <tr><th scope=\"row\">Pull-in delay \/ power-on startup<\/th><td>&lt;50 ms \/ &lt;1 s<\/td><\/tr>\n     <tr><th scope=\"row\">Operating temperature<\/th><td>\u221230 to +50\u00b0C; no frost or condensation<\/td><\/tr>\n     <tr><th scope=\"row\">Storage temperature<\/th><td>\u221240 to +70\u00b0C<\/td><\/tr>\n     <tr><th scope=\"row\">Operating \/ storage humidity<\/th><td>35\u201385% RH \/ 35\u201395% RH; avoid condensation<\/td><\/tr>\n     <tr><th scope=\"row\">Protection rating<\/th><td>IP20<\/td><\/tr>\n     <tr><th scope=\"row\">Dimensions<\/th><td>114.5 \u00d7 99.5 \u00d7 22.5 mm<\/td><\/tr>\n     <tr><th scope=\"row\">Mounting \/ terminals<\/th><td>35 mm DIN rail \/ detachable terminals<\/td><\/tr>\n     <tr><th scope=\"row\">Standards referenced in documentation<\/th><td>EN ISO 13849 \u00b7 IEC 61508 \u00b7 IEC 62061 \u00b7 EN 61000-4 series<\/td><\/tr>\n    <\/tbody>\n   <\/table>\n  <\/div>\n  <p class=\"srb-note\"><strong>Safety-performance scope:<\/strong> The stated component ratings do not automatically establish the machine&#8217;s Category, PL or SIL. Complete performance depends on the input, logic, output, architecture and validation. The module response time is only one part of total system response. Standard references are not an independent third-party certification claim.<\/p>\n  <p class=\"srb-small srb-subsection\">Installation: provide an enclosure suitable for the machine environment, confirm the contact load and supply, and observe the documented temperature and humidity limits.<\/p>\n <\/div>\n<\/section>\n\n<!-- 05: Selection support and resources -->\n<section id=\"faq-resources\" class=\"srb-section srb-light\" aria-labelledby=\"srb-support-title\">\n <div class=\"srb-wrap\">\n  <p class=\"srb-kicker\">Selection Support<\/p>\n  <h2 id=\"srb-support-title\">Plan Your SRB Integration<\/h2>\n  <details><summary>What information should I provide for model and interface review?<\/summary><p>Send the protective-device model, output signal type, NPN \/ PNP requirement, machine supply, downstream control circuit, required safety performance, and any reset or muting requirements.<\/p><\/details>\n  <details><summary>Can I use SRB-2A1B with a different protective device?<\/summary><p>Compatibility depends on the exact output signals, electrical interface and safety architecture. Provide the device&#8217;s technical documentation so these can be checked for the intended application.<\/p><\/details>\n  <details><summary>Which details matter for a material-transfer application?<\/summary><p>Include the opening and load dimensions, direction of travel, operating sequence, sensor arrangement and possible personnel access. These details help define the application-specific muting requirements.<\/p><\/details>\n  <ul class=\"srb-links\" aria-label=\"Related application resources\">\n   <li><a href=\"\/industrial-safety-solutions\/\">Industrial Safety Solutions \u2192<\/a><\/li>\n   <li><a href=\"\/industrial-safety-solutions\/safety-for-packaging\/\">Packaging Machine Safety \u2192<\/a><\/li>\n  <\/ul>\n  <div class=\"srb-cta\">\n   <h3>Discuss Your Machine Safety Application<\/h3>\n   <p>Share your device model and control requirements for SRB-2A1B selection and integration support.<\/p>\n   <a class=\"srb-btn\" href=\"\/contact-us\/\">Contact Us<\/a>\n  <\/div>\n <\/div>\n<\/section>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>CCH \u00b7 Machine Safety Control SRB-2A1B Safety Relay Module Monitor compatible dual-channel safety-device signals and interface with downstream machine safety circuits. Supports selectable NPN \/ PNP inputs, manual or automatic reset, and dedicated muting control inputs. Discuss Your Application View Specifications NPN \/ PNP Selectable dual-channel input 2 NO + 1 NC Relay contacts &lt;10 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1473,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_gspb_post_css":"","footnotes":""},"class_list":["post-1474","page","type-page","status-publish","has-post-thumbnail","hentry"],"_links":{"self":[{"href":"https:\/\/industrialsafetysensor.com\/de\/wp-json\/wp\/v2\/pages\/1474","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/industrialsafetysensor.com\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/industrialsafetysensor.com\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/industrialsafetysensor.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/industrialsafetysensor.com\/de\/wp-json\/wp\/v2\/comments?post=1474"}],"version-history":[{"count":0,"href":"https:\/\/industrialsafetysensor.com\/de\/wp-json\/wp\/v2\/pages\/1474\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/industrialsafetysensor.com\/de\/wp-json\/wp\/v2\/media\/1473"}],"wp:attachment":[{"href":"https:\/\/industrialsafetysensor.com\/de\/wp-json\/wp\/v2\/media?parent=1474"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}